Learning curve analysis of a patient lift-assist device.

نویسندگان

  • Stephanie A Reid
  • Gary A Mirka
چکیده

One of the challenges facing ergonomists in the implementation of an ergonomic solution is addressing the concerns related to their impact on productivity. The focus of the current study was to (1) apply standard learning curve analysis to the learning that takes place as an individual works with a patient handling device and (2) compare the effects of two different training protocols on measures of learning. Eighteen subjects completed 11 replications of a patient transfer task after participating in either an "interactive" training protocol or "see-one-do-one" training protocol. The results show that the learning rate for this task was 83% with no difference as a function of training protocol. The results do indicate that the effect of Training Method was significant (p<0.05) for time to complete the first patient lift task (370s for the interactive training vs. 475s for see-one-do-one training). The results of the analysis of the survey data supported the objective results in that the only measure that was responsive to training type (p<0.05) was related to comfort level in performing the patient lift task for the first time. The results emphasize the importance in considering learning when introducing an intervention in the workplace, and showed that in this instance, training type had an immediate impact on productivity, but that this effect diminished over time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran

Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Management of the VAD Patient for Non-Cardiac Procedures

The patient with a ventricular assist device (VAD) who presents for non-cardiac surgery often presents a challenge to non-cardiac anesthesiologists due to the unfamiliarity most general anesthesia practitioners have with the devices and the physiology of the VAD-supported state, as well as the high level of illness and comorbidity with which many supported patients present. Further, the infrequ...

متن کامل

Impedance Evaluation of a Probe-Coil’s Lift-off and Tilt Effect in Eddy-Current Nondestructive Inspection by 3D Finite Element Modeling

The probe-coil’s lift-off and tilt variations will cause noise signals that can obscure the valuable signals when the surface inspection is performed. Prevention of noise signals due to lift-off and tilt variations is an important element in most eddy current inspections. In this paper, the electromagnetic field and impedance of a cylindrical probe-coil have been calculated numerically for arbi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied ergonomics

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2007