Integration of Large Offshore Wind Farm - Doubly Fed Induction Generators with Classical Hvdc
نویسندگان
چکیده
Due to the fast increase in wind power production there is a need for detailed studies of integration problems. Integration problems arise from the characteristics of wind power and various technologies used in wind energy industry. In this paper, a case study of doubly fed induction generators connected with classical HVDC line commutated converter thyristor bridge is investigated. Operation strategies and corresponding controllers with and without STATCOM are proposed, dynamic models in Matlab/Simulink are developed, and simulation results are presented.
منابع مشابه
Impact of DFIG Based Offshore Wind Farms Connected Through VSC-HVDC Link on Power System Stability
With the increased levels of offshore wind power penetration into power systems, the impact of offshore wind power on stability of power systems require more investigation. In this paper, the effects of a large scale doubly fed induction generator (DFIG) based offshore wind farm (OWF) on power system stability are examined. The OWF is connected to the main onshore grid through a voltage source ...
متن کاملDefinition of a Control Scheme for a Coordinated Management of Large Offshore Wind Farms Connected via Hvdc Links
This paper proposes the development of an appropriate control system for the real-time management of large offshore Doubly-Fed Induction Generator (DFIG) based wind farms, connected to the transmission network by Voltage Source Converter High Voltage Direct Current (VSC-HVDC) link. In this plant layout, variable frequency operation lets wind turbines to work on a wider range of wind speed value...
متن کاملMulti-Period OPF Model of Power Systems with HVDC Connected Intermittent Wind Power Generation
This paper presents a model for a multi-period optimal power flow (MP-OPF) problem which includes offshore wind farm connected to the grid by line-commutated converter high-voltage DC (LCC-HVDC) link. The offshore wind farm is composed of doubly fed induction generators (DFIGs), and the DFIGs capability curve is considered in order to obtain a more realistic dispatch for wind farm. The uncertai...
متن کاملReal-Time Simulation of a Wind Connected HVDC Grid
Real-time simulation of a three-terminal high-voltage directcurrent (HVDC) grid connected to a doubly-fed induction generator (DFIG) based wind farm has been presented in this paper. A recently invented control strategy, known as powersynchronization control, is applied for the integration of the wind farm to the HVDC grid. The dynamic performance study of the system under normal wind power flu...
متن کاملSmall Signal Stability Analysis for a DFIG-Based Offshore Wind Farms Collected Through VSC-HVDC Transmission System
This paper modeled a doubly fed induction generator (DFIG) based offshore wind farm integrated through a voltage source converter –based high voltage direct current (VSC-HVDC) transmission system, which is collected with infinite bus for small signal stability analysis. The control system of HVDC system is considered for the stability analysis. The impact of the VSC control parameters on the ne...
متن کامل