Multiple Axis-Aligned Filters for Rendering of Combined Distribution Effects

نویسندگان

  • Lifan Wu
  • Ling-Qi Yan
  • Alexandr Kuznetsov
  • Ravi Ramamoorthi
چکیده

Distribution effects such as diffuse global illumination, soft shadows and depth of field, are most accurately rendered using Monte Carlo ray or path tracing. However, physically accurate algorithms can take hours to converge to a noise-free image. A recent body of work has begun to bridge this gap, showing that both individual and multiple effects can be achieved accurately and efficiently. These methods use sparse sampling, GPU raytracers, and adaptive filtering for reconstruction. They are based on a Fourier analysis, which models distribution effects as a wedge in the frequency domain. The wedge can be approximated as a single large axis-aligned filter, which is fast but retains a large area outside the wedge, and therefore requires a higher sampling rate; or a tighter sheared filter, which is slow to compute. The state-of-the-art fast sheared filtering method combines low sampling rate and efficient filtering, but has been demonstrated for individual distribution effects only, and is limited by high-dimensional data storage and processing. We present a novel filter for efficient rendering of combined effects, involving soft shadows and depth of field, with global (diffuse indirect) illumination. We approximate the wedge spectrum with multiple axis-aligned filters, marrying the speed of axis-aligned filtering with an even more accurate (compact and tighter) representation than sheared filtering. We demonstrate rendering of single effects at comparable sampling and frame-rates to fast sheared filtering. Our main practical contribution is in rendering multiple distribution effects, which have not even been demonstrated accurately with sheared filtering. For this case, we present an average speedup of 6× compared with previous axis-aligned filtering methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Axis-aligned Filtering for Interactive Physically-based Rendering

Axis-aligned Filtering for Interactive Physically-based Rendering

متن کامل

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Porosity Rendering in High-Performance Architecture: Wind-Driven Natural Ventilation and Porosity Distribution Patterns

Natural ventilation is one of the most essential issues in the concept of high-performance architecture. The porosity has a lot to do with wind-phil architecture to meet high efficiency in integrated architectural design and materialization a high-performance building. Natural ventilation performance in porous buildings is influenced by a wide range of interre...

متن کامل

Optimal Sitting, Sizing, and Operation of Batteries and Passive Filters to Mitigate Over-voltage and Harmonic Problems in Distribution Networks with High Photovoltaic Penetration

Photovoltaic systems (PVs), despite their many advantages, may have effects such as power quality issues (voltage and harmonics increase), short-circuits level increase, protection issues, and transient stability for network. Some of these effects are due to the high PV penetration, which encounters the network with the over-voltage and harmonics problems. In this paper, the location, size and ...

متن کامل

Calculation of wedged dose distributions using an analytical method

Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Comput. Graph. Forum

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2017