Fractionated High-Dose-Rate Brachytherapy
نویسندگان
چکیده
Purpose: A growing body of data suggests that local control in nasopharyngeal cancer (NPC) is related to the radiation dose administered. We conducted a singleinstitution study of high-dose radiotherapy (RT), which incorporated high-dose-rate (HDR) brachytherapy (BT). These results were analyzed together with data obtained from controls who did not receive BT. Patients and Methods: The BT group comprised 42 consecutive patients of whom 29 patients were staged according to the tumor, node, metastasis system as T1 through 3, 13 patients were T4, and 34 patients were N+ disease. BT was administered on an outpatient basis by means of a specially designed flexible nasopharyngeal applicator, and the dose distributions were optimized. Treatment for T1 through 3 tumors comprised 60 Gy of external-beam radiotherapy (ERT) followed by six fractions of 3 Gy BT (two fractions per day). Patients with parapharyngeal tumor extension and/or T4 tumors received 70 Gy ERT and four fractions of 3 Gy BT. The no-BT group consisted of all patients treated from 1965 to 1991 (n = 109), of whom 82 patients had stages T1 through 3, 27 patients had T4, and 80 patients had N+ disease. Multivariate Cox proportional hazards analyses were performed by using the end points time to local failure (TTLF), time to distant failure (TTDF), disease-free survival (DFS), causespecific survival (CSS), and the prognostic factors age, tumor stage, node stage, and grade. Because the overall treatment time varied substantially in the no-BT
منابع مشابه
Pediatric peri-operative fractionated high-dose-rate brachytherapy for recurrent Wilms’ tumor using a reconstructed Freiburg flap
PURPOSE To report peri-operative fractionated high-dose-rate (HDR) brachytherapy with a 3D customized Freiburg flap applicator to treat locally recurrent Wilms' tumor, followed by immediate hyperthermic intraperitoneal chemotherapy for a 16-year-old with a second recurrence of nephroblastoma (Wilms' tumor). MATERIAL AND METHODS The tumor was excised and surgical bed was treated with fractiona...
متن کاملVerification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.
Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...
متن کاملHigh-dose-rate and pulsed-dose-rate brachytherapy for oral cavity cancer and oropharynx cancer
Interstitial brachytherapy represents the treatment of choice for small tumours, regionally localized in the oral cavity and the oropharynx. In the technical setting, continuous low-dose-rate (LDR) brachytherapy represented for many years the gold standard for administering radiation in head and neck brachytherapy. Large series of head and neck cancer patients treated with LDR brachytherapy hav...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملDosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry
Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...
متن کامل