Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.

نویسندگان

  • M K Sridhar
  • R Carter
  • F Moran
  • S W Banham
چکیده

BACKGROUND Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode. METHODS Symptom limited exercise tests were carried out in 24 patients reporting effort intolerance and breathlessness. Exercise testing was performed by bicycle ergometry with a specifically designed protocol involving gradual two minute workload increments. Arterial O2 and CO2 tensions were measured at rest and during exercise by direct blood sampling from an indwelling arterial cannula and a combined transcutaneous electrode heated to 45 degrees C. The transcutaneous system was calibrated against values obtained by direct arterial sampling before each test. RESULTS In all tests the trend of gas exchange measured by the transcutaneous system was true to the trend measured from direct arterial sampling. In the 140 measurements the mean difference between the O2 tensions estimated by direct sampling and the transcutaneous method was 0.08 kPa (0.62 mm Hg, limits of agreement 4.42 and -3.38 mm Hg). The mean difference between the methods for CO2 was 0.02 kPa (0.22 mm Hg, limits of agreement 2.20 and -1.70 mm Hg). There was no morbidity associated with the use of the transcutaneous electrode heated to 45 degrees C. CONCLUSIONS A combined transcutaneous O2 and CO2 electrode heated to 45 degrees C can be used to provide a reliable estimate of gas exchange during gradual incremental exercise in adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introducing Pt/ZnO as a new non carbon substrate electro catalyst for oxygen reduction reaction at low temperature acidic fuel cells

Gas diffusion electrode was used for providing better conditions in fuel cell systems for oxygen reduction reaction (ORR). Because the slow kinetics of the oxygen reduction reaction at the proton exchange membrane fuel cell cathode restricts fuel cell efficiency. To this end, researchers have used platinum-coated carbon. In the present study, due to the reduction of carbon corrosion, Zinc oxide...

متن کامل

Introducing Pt/ZnO as a new non carbon substrate electro catalyst for oxygen reduction reaction at low temperature acidic fuel cells

Gas diffusion electrode was used for providing better conditions in fuel cell systems for oxygen reduction reaction (ORR). Because the slow kinetics of the oxygen reduction reaction at the proton exchange membrane fuel cell cathode restricts fuel cell efficiency. To this end, researchers have used platinum-coated carbon. In the present study, due to the reduction of carbon corrosion, Zinc oxide...

متن کامل

Single walled carbon nanotube in the reaction layer of gas diffusion electrode for oxygen reduction reaction

In this paper, the effect of surface area of reaction layers in gas diffusion electrodes on oxygen reduction reaction was investigated. For this purpose, various amounts (0.1, 0.2, 0.3, 0.4, 0.5, 1, 1.5 and zero %wt of total loading of reaction layer) of single walled carbon nanotube (SWCNT) were inserted in the reaction layer. The performance of gas diffusion electrodes for oxygen reduction re...

متن کامل

Use of a Combined SpO2/PtcCO2 Sensor in the Delivery Room

Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recen...

متن کامل

Estimation of arterial oxygen and carbon dioxide tensions by a single transcutaneous sensor.

A transcutaneous electrochemical sensor designed to estimate arterial oxygen (Pao2) and carbon dioxide (Paco2) tensions simultaneously and continuously was evaluated in newborn infants with respiratory illnesses. After calibration with two dry gas mixtures the sensor gave estimates of Pao2 and Paco2 that were comparable with those obtained by two separate electrodes that are already established...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 6  شماره 

صفحات  -

تاریخ انتشار 1993