Analysis of the electronic crosstalk effect in Terra MODIS long-wave infrared photovoltaic bands using lunar images

نویسندگان

  • Truman Wilson
  • Aisheng Wu
  • Xu Geng
  • Zhipeng Wang
  • Xiaoxiong Xiong
چکیده

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key sensors among the suite of remote sensing instruments on board the Earth Observing System Terra and Aqua spacecrafts. For each MODIS spectral band, the sensor degradation has been measured using a set of on-board calibrators. MODIS also uses lunar observations from nearly monthly spacecraft maneuvers, which bring the Moon into view through the spaceview port, helping to characterize the scan mirror degradation at a different angles of incidence. Throughout the Terra mission, contamination of the long-wave infrared photovoltaic band (LWIR PV, bands 27− 30) signals has been observed in the form of electronic crosstalk, where signal from each of the detectors among the LWIR PV bands can leak to the other detectors, producing a false signal contribution. This contamination has had a noticeable effect on the MODIS science products since 2010 for band 27, and since 2012 for bands 28 and 29. Images of the Moon have been used effectively for determining the contaminating bands, and have also been used to derive correction coefficients for the crosstalk contamination. In this paper, we introduce an updated technique for characterizing the crosstalk contamination among the LWIR PV bands using data from lunar calibration events. This approach takes into account both the “in-band” and “out-of-band” contribution to the signal contamination for each detector in bands 27−30, which is not considered in previous works. The crosstalk coefficients can be derived for each lunar calibration event, providing the time dependence of the crosstalk contamination. Application of these coefficients to Earth-view image data results in a significant reduction in image contamination and a correction of the scene radiance for bands 27 − 30. Also, this correction shows a significant improvement to certain threshold tests in the MODIS Level-2 Cloud Mask. In this paper, we will detail the methodology used to identify and correct the crosstalk contamination for the LWIR PV bands in Terra MODIS. The derived time-dependent crosstalk coefficients will also be discussed. Finally, the impact of the correction on the downstream data products will be analyzed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electronic Crosstalk in Aqua MODIS Long-Wave Infrared Photovoltaic Bands

Recent investigations have discovered that Terra MODerate-resolution Imaging Spectroradiometer (MODIS) long-wave infrared (LWIR) photovoltaic (PV) bands, bands 27–30, have strong crosstalk among themselves. The linear model developed to test the electronic crosstalk effect was instrumental in the first discovery of the effect in Terra MODIS band 27, and through subsequent investigations the mod...

متن کامل

Development and Implementation of an Electronic Crosstalk Correction for Bands 27-30 in Terra MODIS Collection 6

The photovoltaic bands on the long-wave infrared focal plane assembly of Terra MODIS, bands 27–30, have suffered from steadily increasing contamination from electronic crosstalk as the mission has progressed. This contamination has a great impact on MODIS data products, including image striping and radiometric bias in the Level-1B calibrated radiance product, and incorrect retrieval in atmosphe...

متن کامل

Crosstalk Effect in SNPP VIIRS

An investigation has been carried out to examine the crosstalk contamination in the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) spacecraft. Prior to this study, the cause of the pronounced striping in Earth View (EV) images and obvious discontinuity in the EV brightness temperature (BT) of the thermal emissive bands (TEB) during...

متن کامل

Investigation and Mitigation of the Crosstalk Effect in Terra MODIS Band 30

It has been previously reported that thermal emissive bands (TEB) 27–29 in the Terra (T-) MODerate resolution Imaging Spectroradiometer (MODIS) have been significantly affected by electronic crosstalk. Successful linear theory of the electronic crosstalk effect was formulated, and it successfully characterized the effect via the use of lunar observations as viable inputs. In this paper, we repo...

متن کامل

Results of MODIS Band-to-band Registration Characterization Using On-orbit Lunar Observations

Since launch, lunar observations have been made regularly by both Terra and Aqua MODIS and used for a number of sensor calibration and characterization related applications, including radiometric stability monitoring, spatial characterization, optical leak and electronic cross-talk characterization, and calibration inter-comparison. MODIS has 36 spectral bands with a total of 490 individual det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016