The aim of the study was to determine the degree of compliance of Polish laboratories with World Health Organization (WHO) recommendations, with regard to semen analysis methodology. A survey requesting information about methods of semen analysis was distributed to employees of 55 laboratories. Respondents who had participated in external seminological workshops (31%) were termed certified respondents (CR), the remaining (69%)-non-certified respondents (NCR). Only one laboratory (6%) in the CR group and none in the NCR were compliant with WHO guidelines for methods and equipment used to evaluate seminal volume, sperm motility, concentration, vitality and morphology. Most problems were of volume measurement (weighing method was reported by 17% of CR and 10% of NCR) and staining method for sperm morphology (Papanicolau or Diff-Quik were found in 33% of CR and 23% of NCR). A three- or four-point grading of sperm motility was used by the majority of respondents; however, 17% of CR and 37% of NCR did not use a laboratory counter to tally spermatozoa. Although a haemocytometer method was used by 80% of laboratories in each group, the improved Neubauer chamber was used only by 42% of CR and 19% of NCR. In each group, 24% of laboratories did not perform a vitality test. Procedural errors and the interchangeable utilization of two or even three methods to analyse a given parameter was observed in both groups. The results indicate a need for standardisation of the methods and continuous, unified training in semen analysis in Polish laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-5: Semen Analysis - Clinical Laboratories; Is Standardization Applied?

Reduced semen quality is commonly claimed to be one of the main signs of male infertility and thus, analysis of semen is recommended as the cornerstone of a male fertility investigation. However, to control possible sources of physiological and methodological variation, and to generate reliable information on semen quality that can be accurately compared across different laboratories, semen ana...

متن کامل

Evaluation of the Standardization in Semen Analysis Performance According to the WHO Protocols Among Laboratories in Tehran, Iran

Background and Objective: Infertility refers to the failure in achieving pregnancy of a couple after one year of regular sexual intercourse without using a protection method. The purpose of this research work was to evaluate the current status of the test and quality control performance in semen analysis in selected laboratories. Material and Methods: The...

متن کامل

A survey on the status of semen analysis in 118 laboratories in China.

Collecting baseline information on how laboratories perform testing is a reasonable first step towards establishing intra- and inter-laboratory standardization and quality control for semen analysis. We carried out a survey of the laboratories performing the testing in Mainland China. A questionnaire, composed of 36 questions covering all aspects of semen analysis, was designed, and a copy was ...

متن کامل

I-4: External Quality Assessment - A Necessity in The Andrology Laboratory

Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...

متن کامل

Reducing Inter-Laboratory Differences between Semen Analyses Using Z Score and Regression Transformations

Background Standardization of the semen analysis may improve reproducibility. We assessed variability between laboratories in semen analyses and evaluated whether a transformation using Z scores and regression statistics was able to reduce this variability. MaterialsAndMethods We performed a retrospective cohort study. We calculated between-laboratory coefficients of variation (CVB) for sperm c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Asian journal of andrology

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 2013