BACKGROUND Confocal Laser Scanning Microscopy (CLSM) provides the opportunity to perform 3D DNA content measurements on intact cells in thick histological sections. So far, sample size has been limited by the time consuming nature of the technology. Since the power of DNA histograms to resolve different stemlines depends on both the sample size and the coefficient of variation (CV) of histogram peaks, interpretation of 3D CLSM DNA histograms might be hampered by both a small sample size and a large CV. The aim of this study was to analyze the required CV for 3D CLSM DNA histograms given a realistic sample size. METHODS By computer simulation, virtual histograms were composed for sample sizes of 20000, 10000, 5000, 1000, and 273 cells and CVs of 30, 25, 20, 15, 10 and 5%. By visual inspection, the histogram quality with respect to resolution of G0/1 and G2/M peaks of a diploid stemline was assessed. RESULTS As expected, the interpretability of DNA histograms deteriorated with decreasing sample sizes and higher CVs. For CVs of 15% and lower, a clearly bimodal peak pattern with well distinguishable G0/1 and G2/M peaks were still seen at a sample size of 273 cells, which is our current average sample size with 3D CLSM DNA cytometry. CONCLUSIONS For unambiguous interpretation of DNA histograms obtained using 3D CLSM, a CV of at most 15% is tolerable at currently achievable sample sizes. To resolve smaller near diploid stemlines, a CV of 10% or better should be aimed at. With currently available 3D imaging technology, this CV is achievable.
منابع مشابه
Confocal 3D DNA Cytometry: Assessment of Required Coefficient of Variation By Computer Simulation
To the Editor, Ploeger et al. [4] presented an important work that provides accuracy criteria for assessing the DNA ploidy in thick histological sections. The work relates to image cytometry performed with a confocal microscope , a method that advances lately from research to clinical applications [1]. The success of the microscopy-based assessment is based on many parameters that have to be st...
متن کاملImplementation of Accurate and Fast DNA Cytometry by Confocal Microscopy in 3D
BACKGROUND DNA cytometry is a powerful method for measuring genomic instability. Standard approaches that measure DNA content of isolated cells may induce selection bias and do not allow interpretation of genomic instability in the context of the tissue. Confocal Laser Scanning Microscopy (CLSM) provides the opportunity to perform 3D DNA content measurements on intact cells in thick histologica...
متن کاملCamera Arrangement in Visual 3D Systems using Iso-disparity Model to Enhance Depth Estimation Accuracy
In this paper we address the problem of automatic arrangement of cameras in a 3D system to enhance the performance of depth acquisition procedure. Lacking ground truth or a priori information, a measure of uncertainty is required to assess the quality of reconstruction. The mathematical model of iso-disparity surfaces provides an efficient way to estimate the depth estimation uncertainty which ...
متن کاملQuality assessment of Zarrinehroud River Using Qual2k Simulation Model
Background& objectives: Zarrinehrud River is one of the most important permanent and water-rich rivers in West Azerbaijan province located in the catchment area of Lake Urmia. In this study, to evaluate the quality of the Zarrinehrud River, with a length of 57.5 kilometers from the outlet of Noroozlou to the drainage dam to the Lake Urmia, QUAL2K computer simulation model was used. Methods: Th...
متن کامل3D finite element study of temperature variations during equal channel angular pressing
Equal channel angular pressing is the most promising method of severe plastic deformation with the capability of producing ultrafine grained materials. These materials exhibit improved mechanical and physical properties compared with their coarse grained counter parts.The temperature variation in the sample during ECA-pressing is a key factor determining the final microstructure and mechanical ...
متن کامل