Accuracy of a real-time surgical navigation system for the placement of quad zygomatic implants in the severe atrophic maxilla: A pilot clinical study.

نویسندگان

  • Kuo-Feng Hung
  • Feng Wang
  • Hao-Wei Wang
  • Wen-Jie Zhou
  • Wei Huang
  • Yi-Qun Wu
چکیده

BACKGROUND A real-time surgical navigation system potentially increases the accuracy when used for quad-zygomatic implant placement. PURPOSE To evaluate the accuracy of a real-time surgical navigation system when used for quad zygomatic implant placement. MATERIALS AND METHODS Patients with severely atrophic maxillae were prospectively recruited. Four trajectories for implants were planned, and zygomatic implants were placed using a real-time surgical navigation system. The planned-placed distance deviations at entry (entry deviation)points, exit (exit deviation) points, and angle deviation of axes (angle deviation) were measured on fused operation images. The differences of all the deviations between different groups, classified based on the lengths and locations of implants, were analysed. A P value of < 0.05 indicated statistical significance. RESULTS Forty zygomatic implants were placed as planned in 10 patients. The entry deviation, exit deviation and angle deviation were 1.35 ± 0.75 mm, 2.15 mm ± 0.95 mm, and 2.05 ± 1.02 degrees, respectively. The differences of all deviations were not significant, irrespective of the lengths (P = .259, .158, and .914, respectively) or locations of the placed implants (P = .698, .072, and .602, respectively). CONCLUSION A real-time surgical navigation system used for the placement of quad zygomatic implants demonstrated a high level of accuracy with only minimal planned-placed deviations, irrespective of the lengths or locations of the implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial

Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...

متن کامل

Eye-Lid approach for four zigomatic implant placement in the severely reabsorbed maxillae: technical note.

Up to date, zygomatic implants (ZIs) have been considered a predictable treatment modality for cases of atrophic maxilla. In some severe cases with severe vertical and/or horizontal bone resorption in the anterior maxilla, the placement of standard implants in the anterior area represents a challenge. In these arduous scenarios, performance of a zygomatic "quad-approach" might be advocated. Nev...

متن کامل

A prospective clinical study on titanium implants in the zygomatic arch for prosthetic rehabilitation of the atrophic edentulous maxilla with a follow-up of 6 months to 5 years.

BACKGROUND Prosthetic rehabilitation with implant-supported prostheses in the atrophic edentulous maxilla often requires a bone augmentation procedure to enable implant placement and integration. However, a rigid anchorage can also be achieved by using so-called zygomatic implants placed in the zygomatic arch in combination with regular implants placed in residual bone. PURPOSE The aim of the...

متن کامل

Rehabilitation with zygomatic implants: a treatment option for the atrophic edentulous maxilla--9-year follow-up.

This article reports the 9-year clinical outcome of the two-stage surgical rehabilitation of a severely atrophic edentulous maxilla with a metal-resin fixed denture supported by implants anchored in the zygomatic bone and the maxilla. After clinical and radiographic examination, zygomatic implants were inserted bilaterally and four standard implants were placed in the anterior region of the max...

متن کامل

Restoration of the edentulous maxilla using extrasinus zygomatic implants combined with anterior conventional implants: a retrospective study.

PURPOSE To report on the clinical outcome of 150 extrasinus zygomatic implants placed lateral to the maxillary sinus and combined with conventional implants in the anterior maxilla for the implant-supported rehabilitation of the edentulous maxilla. MATERIALS AND METHODS All patients included in this study presented with completely or partially edentulous maxillae with any remaining teeth indi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2017