Reference values of capillary blood saturation in neonates and its difference from pulse oximetry.

نویسندگان

  • Milos M Jesić
  • Maja D Jesić
  • Tamara D Krstajić
  • Zoran M Vujnović
  • Nedjo D Cutura
  • Svjetlana S Maglajlić
چکیده

INTRODUCTION Haemoglobin saturation is an obligatory oxygen parameter in the assessment of neonatal oxygenation. Although, pulse oximetry is currently one of the major methods in the determination of haemoglobin saturation, capillary blood saturation is still present in the diagnostic process. As well known, haemoglobin saturation value of capillary blood is insufficiently accurate, but not as much as the difference in relation to the values determined by pulse oximetry. Until now published studies have reported that capillary samples are obtained according to a protocol by the principle of free blood outflow, which is practically almost unachievable in the neonate. OBJECTIVE Determination of the reference values of oxygen saturation (SCO2) and partial pressure (pcO2) of capillary blood by squeezing of the foot. The determination of difference between ScO2 and pulse oximetry (SpO2). METHODS In 134 term newborns, we determined SpO2. Subsequently, we measured the values of ScO2 and pcO2 from the same extremity. While withdrawing a capillary sample, we exerted multiple squeezing of the foot. The mean value of ScO2, pcO2, SpO2 and the difference between ScO2 and SpO2 were determined. RESULTS Mean ScO2 value was 80.5 +/- 8.5%, pcO2 was 48.2 +/- 11.4 mm Hg and SpO2 was 98 +/- 1.9%. The difference between ScO2 and SpO2 values was 17.5 +/- 8.6% (t = 23.568; p = 0.000). CONCLUSION There is a statistically highly significant difference between the values of ScO2 and SpO2. Having the knowledge of this difference can increase the accuracy of clinical evaluation and further diagnostics. Comparison in up-to-now conducted studies suggests that the squeezing of the foot for obtaining a capillary sample in relation to free blood outflow does not bear any significant influence on the resultant values of haemoglobin saturation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

Validation of Oxygen Saturation Monitoring In

www.ajcconline.org • BACKGROUND Pulse oximetry is commonly used to monitor oxygenation in neonates, but cannot detect variations in hemoglobin. Venous and arterial oxygen saturations are rarely monitored. Few data are available to validate measurements of oxygen saturation in neonates (venous, arterial, or pulse oximetric). • PURPOSE To validate oxygen saturation displayed on clinical monitors ...

متن کامل

Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.

OBJECTIVE Arterial oxygen saturation (Sao(2)) and arterial carbon dioxide partial pressure (Paco(2)) are 2 of the most important respiratory parameters in the treatment of critically ill neonates. Noninvasive monitoring of these parameters is desirable for continuous estimating of the respiratory status and reducing blood loss because of repeated blood gas analyses. Transcutaneous measurement o...

متن کامل

Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...

متن کامل

Evaluation of Pulse Oximetry in the Early Diagnosis of Cardiac and NonCardiac Diseases in Healthy Newborns

Background: Critical congenital heart diseases (CCHDs) are among the most common birth malformations. This study aimed to determine the cardiac and noncardiac diseases in the Iranian healthy newborns using pulse oximetry (POX) as a suggested screening method.Methods: In this cross-sectional study, healthy term and near term neonates who were born from October 2017 to March 2018 were evalu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Srpski arhiv za celokupno lekarstvo

دوره 138 5-6  شماره 

صفحات  -

تاریخ انتشار 2010