Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm.

نویسندگان

  • Sean R H Davidson
  • I Alex Vitkin
  • Michael D Sherar
  • William M Whelan
چکیده

BACKGROUND AND OBJECTIVES Fluoroptic sensors are used to measure interstitial temperatures but their utility for monitoring laser interstitial thermal therapy (LITT) is unclear because these sensors exhibit a measurement artefact when exposed to the near-infrared (NIR) treatment light. This study investigates the cause of the artefact to determine whether fluoroptic sensors can provide reliable temperature measurements during LITT. STUDY DESIGN/MATERIALS AND METHODS The temperature rise measured by a fluoroptic sensor irradiated in non-absorbing media (air and water) was considered an artefact. Temperature rise was measured as a function of distance from a laser source. Two different sensor designs and several laser powers were investigated. A relationship between fluence rate and measurement artefact in water was determined and coupled with a numerical simulation of LITT in liver to estimate the error in temperature measurements made by fluoroptic sensors in tissue in proximity to the laser source. The effect of ambient light on the performance of sensors capped with a transparent material ("clear-capped sensors") was also investigated. RESULTS The temperature rise recorded in air by both clear- and black-capped fluoroptic sensors decreased with distance from a laser source in a manner similar to fluence rate. Sensor cap material, laser power, and the thermal properties of the surrounding medium affected the magnitude of the artefact. Numerical simulations indicated that the accuracy of a clear-capped fluoroptic sensor used to monitor a typical LITT treatment in liver is > 1 degrees C provided the sensor is further than approximately 3 mm from the source. It was also shown that clear-capped fluoroptic sensors are affected by ambient light. CONCLUSIONS The measurement artefact experienced by both black-capped and clear-capped fluoroptic sensors irradiated by NIR light scales with fluence rate and is due to direct absorption of the laser light, which results in sensor self-heating. Clear-capped fluoroptic sensors can be used to accurately monitor LITT in tissue but should be shielded from ambient light.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The thermal effects of therapeutic lasers with 810 and 904 nm wavelengths on human skin.

OBJECTIVE To investigate the effect of therapeutic infrared class 3B laser irradiation on skin temperature in healthy participants of differing skin color, age, and gender. BACKGROUND Little is known about the potential thermal effects of Low Level Laser Therapy (LLLT) irradiation on human skin. METHODS Skin temperature was measured in 40 healthy volunteers with a thermographic camera at la...

متن کامل

Comparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths

Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (c...

متن کامل

In-vitro Study of Photothermal Anticancer Activity of Carboxylated Multiwalled Carbon Nanotubes

Background and Objective: Multi-walled Carbon Nano Tubes (MWCNTs) as an important element of nanosciences have a remarkable absorption in the region of NIR window (650-900 nm) which can overcome the limitations of deep treatment in photothermal therapy. To disperse MWCNTs in water, it is proposed to attach carboxylated functional group (-COOH) to MWCNTs in order to increase dispersivity in wate...

متن کامل

Gold-Curcumin Nanostructure in Photo-thermal Therapy on Breast Cancer Cell Line: 650 and 808 nm Diode Lasers as Light Sources

Background: Au nanoparticles (AuNPs) exhibit very unique physiochemical and optical properties, which now are extensively studied in a range of medical diagnostic and therapeutic applications. AuNPs can be used for cancer clinical treatment with minimal invasion. On the other hand, curcumin is a polyphenol derived from turmeric which is used for medical purposes due to its anti...

متن کامل

Compared the Effect of Red and Infrared Low-Level Lasers on Folliculogenesis Cycle with the Effect of Clomiphene Drug in Rat’s Ovarian Tissue

Introduction: Folliculogenesis is a cycle that any disruption in this cycle leads to disease. Treatment include Surgery, drugs and low-power lasers have been used as complementary. This study investigated photo-bio-stimulation effect of lasers (power<250 mW)) on folliculogenesis cycle in rats’ ovarian tissue in two wavelength 630 and 810 nm autonomously. Methods: Twenty-eight female Wistar rat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2005