Peripheral aberrations in the human eye for different wavelengths: off-axis chromatic aberration

نویسندگان

  • Bart Jaeken
  • Linda Lundström
  • Pablo Artal
چکیده

The interest in the eye’s off-axis aberrations has increased strongly. On-axis the conversion of the aberration magnitude between different wavelengths is well known. We verified if this compensation is correct also for off-axis measurements by building a wavelength tunable peripheral Hartmann–Shack sensor and measuring 11 subjects out to 30° in the horizontal visual field. At the fovea, an average longitudinal chromatic aberration of 1D between red (671nm) and blue (473nm) light was found, and it increased slightly with eccentricity (up to 1:2D). A similar trend was measured for astigmatism as a function of wavelength (increase ∼0:15D). Computational ray tracing in model eyes showed that the origin of the small increase of chromatic aberrations with eccentricity is the change of the oblique power of the refractive surfaces in the eye. Factors related to increase of axial length and refractive index of the eye were found to have a very small influence. © 2011 Optical Society of America OCIS codes: 330.0330, 120.4570.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced...

متن کامل

A new approach to the study of ocular chromatic aberrations

We measured the ocular wavefront aberration at six different visible wavelengths (between 450 and 650 nm) in three subjects, using a spatially resolved refractometer. In this technique, the angular deviation of light rays entering the pupil at different locations is measured with respect to a target viewed through a centered pupil. Fits of the data at each wavelength to Zernike polynomials were...

متن کامل

Lens Aberrations and Ray Tracing

When beam quality is a concern in an optical setup, lens aberrations are an undesired side-effect. Which aberration affects a particular experiment is not always as obvious as one would like. Take for example, the simple goal to concentrate the maximum amount of optical power at a certain point using a lens. The first “obvious” requirement is that the initial beam should be well collimated, sen...

متن کامل

Investigating sources of variability of monochromatic and transverse chromatic aberrations across eyes

Schematic eye models have typically been used to explain the average monochromatic and chromatic imaging properties of the eye. Both monochromatic aberrations and transverse chromatic aberration are known to vary widely across subjects. However, to our knowledge, the ability of schematic eye models to predict these individual variations has not been tested experimentally. We used a spatially re...

متن کامل

In vivo chromatic aberration in eyes implanted with intraocular lenses.

PURPOSE To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). METHODS EIGHTEEN EYES PARTICIPATED IN THIS STUDY: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011