Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue.
نویسندگان
چکیده
The absorption and transport scattering coefficients of biological tissues determine the radial dependence of the diffuse reflectance that is due to a point source. A system is described for making remote measurements of spatially resolved absolute diffuse reflectance and hence noninvasive, noncontact estimates of the tissue optical properties. The system incorporated a laser source and a CCD camera. Deflection of the incident beam into the camera allowed characterization of the source for absolute reflectance measurements. It is shown that an often used solution of the diffusion equation cannot be applied for these measurements. Instead, a neural network, trained on the results of Monte Carlo simulations, was used to estimate the absorption and scattering coefficients from the reflectance data. Tests on tissue-simulating phantoms with transport scattering coefficients between 0.5 and 2.0 mm(-1) and absorption coefficients between 0.002 and 0.1 mm(-1) showed the rms errors of this technique to be 2.6% for the transport scattering coefficient and 14% for the absorption coefficients. The optical properties of bovine muscle, adipose, and liver tissue, as well as chicken muscle (breast), were also measured ex vivo at 633 and 751 nm. For muscle tissue it was found that the Monte Carlo simulation did not agree with experimental measurements of reflectance at distances less than 2 mm from the incident beam.
منابع مشابه
Influence of the phase function on determination of the optical properties of biological tissue by spatially resolved reflectance.
Spatially resolved reflectance measurements are widely used for determination of the optical properties of biological media. However, the influence of the phase function on these measurements has not been quantified. We show that errors in the derived reduced scattering and absorption coefficients are as great as 100% for both absolute and relative spatially resolved reflectance measurements if...
متن کاملDetermination of the optical properties of turbid media by measurements of the spatially resolved reflectance considering the point-spread function of the camera system.
The radial dependence of the diffuse reflectance from a turbid medium that is due to a point source is basically influenced by the absorption and reduced scattering coefficients. A system consisting of a HeNe laser source and a CCD camera is described for making remote measurements of the spatially resolved diffuse reflectance. Liquid tissue phantoms were made of Intralipid and trypan blue to v...
متن کاملFiber-optic probe for noninvasive real-time determination of tissue optical properties at multiple wavelengths.
We present a compact, fast, and versatile fiber-optic probe system for real-time determination of tissue optical properties from spatially resolved continuous-wave diffuse reflectance measurements. The system collects one set of reflectance data from six source-detector distances at four arbitrary wavelengths with a maximum overall sampling rate of 100 Hz. Multivariate calibration techniques ba...
متن کاملIn vivo local determination of tissue optical properties: applications to human brain.
Local and superficial near-infrared (NIR) optical-property characterization of turbid biological tissues can be achieved by measurement of spatially resolved diffuse reflectance at small source-detector separations (<1.4 mm). However, in these conditions the inverse problem, i.e., calculation of localized absorption and the reduced scattering coefficients, is necessarily sensitive to the scatte...
متن کاملUsing an oblique incident laser beam to measure the optical properties of stomach mucosa/submucosa tissue
BACKGROUND The purpose of the study is to determine the optical properties and their differences for normal human stomach mucosa/submucosa tissue in the cardiac orifice in vitro at 635, 730, 808, 890 and 980 nm wavelengths of laser. METHODS The measurements were performed using a CCD detector, and the optical properties were assessed from the measurements using the spatially resolved reflecta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 35 13 شماره
صفحات -
تاریخ انتشار 1996