Pulse Rate Analysis from the Photoplethysmographic Signal for Turbulence Detection

نویسندگان

  • E. Gil
  • P. Laguna
  • J. P. Martínez
  • L. Sörnmo
چکیده

In this paper we assessed the possibility of using the pulse rate (PR) extracted from the photoplethysmographic signal for turbulence detection as an alternative to the heart rate (HR). The study is based on analysis of the rhythm changes observed during 4131 ventricular premature beats of 27 subjects. Classical features for turbulence analysis, turbulence onset and turbulence slope were estimated based on HR and PR. Then, patients were classified as turbulence or no-turbulence based on PR features, the accuracy of the method was evaluated considering subjects classification based on HR as the reference. Features analyzed produce an Acc=95% in turbulence detection and subject classification among HR turbulence categories produce an Acc=91% for PR analysis. These results show that PR analysis could be used as a surrogate technique for turbulence detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Virtual Instrumentation based Non-Invasive Assessment of Arterial Stiffness Using Finger Photoplethysmographic Signal

Cardiovascular disease (CVD) is currently the biggest single cause of mortality in the world; hence, the early detection of its onset is vital for effective prevention therapies. Arterial Stiffness (AS) has proved to be a direct indicator for CVD. In this study, a non-invasivemethod for assessing AS using Finger Photoplethysmographic (PPG) Signal is proposed. Virtual Instrumentation(VI) softwar...

متن کامل

Increasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method

Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...

متن کامل

Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

BACKGROUND Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. METHODS In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After in...

متن کامل

A Mthod for Generating the Turbulent Intermittency Function

A detection method based on sensitization of a squared double differentiated signal is developed which discriminates the turbulent zones from laminar zones quite accurately. The procedure adopts a variable threshold and a variable hold time of the order of the Kolmogorov time scale. The output file so generated, includes all the information for further analysis of the turbulent signal.

متن کامل

An Efficient and Automatic Systolic Peak Detection Algorithm for Photoplethysmographic Signals

Processing of physiological signals often involves detection of peaks and finding intervals between them. Well developed methods are available for Electrocardiogram(ECG) QRS complex detection. However, there are only a few algorithms published for peak detection suitable for pulse wave signals such as arterial pressure wave and photoplethysmographic (PPG) signals. Algorithms for detection of QR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012