Correction: Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography
نویسندگان
چکیده
PURPOSE To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL) in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction. METHODS The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated. RESULTS Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09), and in venous sets of 73.3 versus 79.4 (p = 0.15), respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01). Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase. CONCLUSION Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.
منابع مشابه
Initial experience with 64-slice cardiac CT: non-invasive visualization of coronary artery bypass grafts.
AIMS The aim of this study was to evaluate the diagnostic accuracy in the assessment of coronary artery bypass grafts using 64-slice computed tomography (CT) technology. METHODS AND RESULTS CT coronary angiography was performed for 96 bypasses in 31 patients with suspected coronary artery disease using a Siemens Sensation 64-slice CT-scanner and compared with invasive coronary angiography (IC...
متن کاملNon-invasive assessment of coronary artery bypass grafts and native coronary arteries using 64-slice computed tomography: comparison with invasive coronary angiography.
INTRODUCTION AND OBJECTIVES Although the diagnostic accuracy of CT in the non-invasive assessment of coronary arteries and grafts is known to be high, only a few studies have investigated the technique's reliability for the combined assessment of native coronary arteries, grafts, and vessels lying distal to anastomoses. The aim of this study was to evaluate the diagnostic accuracy of 64-slice C...
متن کامل3D-CT arteriography and 3D-CT venography: the separate demonstration of arterial-phase and venous-phase on 3D-CT angiography in a single procedure.
Although 3D-CT angiography provides valuable anatomic information regarding lesion and their surrounding vessels and bony structures, it cannot demonstrate lesions, arteries, and veins, separately. The separate demonstration of arterial-phase 3D-CT angiography (3D-CT arteriography) and venous-phase 3D-CT angiography (3D-CT venography) will facilitate the understanding of the vascular anatomy wi...
متن کاملCT angiography as a confirmatory test in diagnosis of brain death: comparison between three scoring systems.
PURPOSE Computed tomography (CT) angiography emerges as a viable alternative technique for confirmation of brain death. However, evaluation criteria are not well established for demonstration of cerebral circulatory arrest. This retrospective study aimed to evaluate CT angiography scoring systems in diagnosis of brain death, review the literature, and compare interobserver agreement between dif...
متن کاملComparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کامل