Diagnostic Performance of Hybrid Cardiac Imaging Methods for Assessment of Obstructive Coronary Artery Disease Compared With Stand-Alone Coronary Computed Tomography Angiography: A Meta-Analysis.

نویسندگان

  • Asim Rizvi
  • Donghee Han
  • Ibrahim Danad
  • Bríain Ó Hartaigh
  • Ji Hyun Lee
  • Heidi Gransar
  • Wijnand J Stuijfzand
  • Hadi Mirhedayati Roudsari
  • Mahn Won Park
  • Jackie Szymonifka
  • Hyuk-Jae Chang
  • Erica C Jones
  • Paul Knaapen
  • Fay Y Lin
  • James K Min
  • Jessica M Peña
چکیده

OBJECTIVES The current meta-analysis aimed to evaluate the diagnostic performance of hybrid cardiac imaging techniques compared with stand-alone coronary computed tomography angiography (CTA) for assessment of obstructive coronary artery disease (CAD). BACKGROUND The usefulness of coronary CTA for detecting obstructive CAD remains suboptimal at present. Myocardial perfusion imaging encompasses positron emission tomography, single-photon emission computed tomography, and cardiac magnetic resonance, which permit the identification of myocardial perfusion defects to detect significant CAD. A hybrid approach comprising myocardial perfusion imaging and coronary CTA may improve diagnostic performance for detecting obstructive CAD. METHODS PubMed and Web of Knowledge were searched for relevant publications between January 1, 2000 and December 31, 2015. Studies using coronary CTA and hybrid imaging for diagnosis of obstructive CAD (a luminal diameter reduction of >50% or >70% by invasive coronary angiography) were included. In total, 12 articles comprising 951 patients and 1,973 vessels were identified, and a meta-analysis was performed to determine pooled sensitivity, specificity, and summary receiver-operating characteristic curves. RESULTS On a per-patient basis, the pooled sensitivity of hybrid imaging was comparable to that of coronary CTA (91% vs. 90%; p = 0.28). However, specificity was higher for hybrid imaging versus coronary CTA (93% vs. 66%; p < 0.001). On a per-vessel basis, sensitivity for hybrid imaging against coronary CTA was comparable (84% vs. 89%; p = 0.29). Notably, hybrid imaging yielded a specificity of 95% versus 83% for coronary CTA (p < 0.001). Summary receiver-operating characteristic curves displayed improved discrimination for hybrid imaging beyond coronary CTA alone, on a per-vessel basis (area under the curve: 0.97 vs. 0.93; p = 0.047), although not on a per-patient level (area under the curve: 0.97 vs. 0.93; p = 0.132). CONCLUSIONS Hybrid cardiac imaging demonstrated improved diagnostic specificity for detection of obstructive CAD compared with stand-alone coronary CTA, yet improvement in overall diagnostic performance was relatively limited.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

Imaging Cardiac Positron Emission Tomography/Computed Tomography Imaging Accurately Detects Anatomically and Functionally Significant Coronary Artery Disease

Background—Computed tomography (CT) is increasingly used to detect coronary artery disease, but the evaluation of stenoses is often uncertain. Perfusion imaging has an established role in detecting ischemia and guiding therapy. Hybrid positron emission tomography (PET)/CT allows combination angiography and perfusion imaging in short, quantitative, low-radiation-dose protocols. Methods and Resul...

متن کامل

Diagnostic Performance of Coronary CT Angiography and Myocardial Perfusion Imaging in Kidney Transplantation Candidates.

OBJECTIVES The goal of this study was to compare the diagnostic accuracy of the coronary artery calcium score (CACS), coronary computed tomography angiography (CTA), single-photon emission computed tomography (SPECT), and a combination of these tools in the diagnosis of obstructive coronary artery disease (CAD) in patients with chronic kidney disease referred for cardiac evaluation before kidne...

متن کامل

Prognostic value of cardiac hybrid imaging integrating single-photon emission computed tomography with coronary computed tomography angiography.

Aims Although cardiac hybrid imaging, fusing single-photon emission computed tomography (SPECT) myocardial perfusion imaging with coronary computed tomography angiography (CCTA), provides important complementary diagnostic information for coronary artery disease (CAD) assessment, no prognostic data exist on the predictive value of cardiac hybrid imaging. Hence, the aim of this study was to asse...

متن کامل

Obstructive sleep apnea and the severity of coronary artery disease

Background: It has been implicated that obstructive sleep apnea (OSA) is associated with increased risk of&nbsp;cardiovascular disease including stroke, myocardial infarction, coronary artery disease (CAD) and hypertension. The aim of this study was to investigate the correlation between OSA and severity of atherosclerosis assessed by angiography. Methods: This study included 337 patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 11 4  شماره 

صفحات  -

تاریخ انتشار 2018