T2 mapping of the heart with high temporal and spatial resolution using a radial double inversion fast spin-echo pulse sequence with view sharing

نویسندگان

  • Maria Altbach
  • Tomoe Barr
  • Jaspreet Singh
  • Bujji Ainapurapu
  • Dipak Kc
  • Scott Squire
  • Jean-Philippe Galons
  • Chuan Huang
  • Aiden Abidov
چکیده

Background While DE imaging is considered a gold standard in the evaluation of myocardial scar/viability in patients with old MI or cardiomyopathy, a few recent publications demonstrate a higher diagnostic sensitivity of T2weighted techniques in patients with Non-STEMI and myocarditis where changes in T2-weighting are due to inflammation in the myocardium leading to edema (Abdel-Aty H, JACC 53:1194, 2009; Tilak GS, Invest Radiol 43:7, 2008). Thus, recently there has been great interest in measuring T2, the parameter responsible for contrast in T2weighted images (Giri S, JCMR 11:56, 2009; Kim D Magn Reson Med 62:300, 2009). Most proposed methods, however, do not have adequate spatial and temporal resolution for detecting subtle changes in the myocardium T2 or are affected by artifacts caused by motion and flow. Our group developed a Double Inversion Radial Fast Spin Echo (DIR-RADFSE) sequence that yields TE images and T2 maps of the heart, with fewer motion and flow artifacts compared to conventional methods. DIR-RADFSE yields data for 16 perfectly registered TE images (in plane resolution ~ 1.3-1.6 mm). The TE images are used for the voxel-wise generation T2 maps. The high temporal resolution afforded by DIR-RADFSE allows for accurate T2 estimation. The high spatial resolution enables detecting T2 changes in small areas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation

BACKGROUND The abnormal signal intensity in cardiac T2-weighted images is associated with various pathologies including myocardial edema. However, the assessment of pathologies based on signal intensity is affected by the acquisition parameters and the sensitivities of the receiver coils. T2 mapping has been proposed to overcome limitations of T2-weighted imaging, but most methods are limited i...

متن کامل

Accelerated Breath-Hold Multi-Echo FSE Pulse Sequence Using Compressed Sensing and Parallel Imaging for T2 Measurement in the Heart

Introduction: Measurement of proton transverse relaxation time (T2) can be used to detect pathological changes in tissue for a variety of clinical applications, including identification of edema and iron overload. The most widely used T2 mapping pulse sequence is the Carr-Purcell-Meiboom-Gill (CPMG) sequence [1,2]. For body MRI, however, a CPMG pulse sequence is typically performed with navigat...

متن کامل

Improved dark blood imaging of the heart using radial balanced steady-state free precession

BACKGROUND Dark blood imaging of the heart is conventionally performed using a breath-hold, dual-inversion Cartesian fast spin-echo pulse sequence. Our aim was to develop a faster, more flexible approach that would be less motion-sensitive and provide better image quality. For this purpose, we implemented a prototype radial balanced steady-state free precession (bSSFP) pulse sequence. METHODS...

متن کامل

Accelerated and motion-robust in vivo T2 mapping from radially undersampled data using bloch-simulation-based iterative reconstruction.

PURPOSE Development of a quantitative transverse relaxation time (T2)-mapping platform that operates at clinically feasible timescales by employing advanced image reconstruction of radially undersampled multi spin-echo (MSE) datasets. METHODS Data was acquired on phantom and in vivo at 3 Tesla using MSE protocols employing radial k-space sampling trajectories. In order to overcome the nontriv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012