Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

نویسندگان

  • Kousuke Iba
  • Yasuhiro Ozasa
  • Takuro Wada
  • Tomoaki Kamiya
  • Toshihiko Yamashita
  • Mitsuhiro Aoki
چکیده

BACKGROUND The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the radial styloid screws using a biomechanical study in a cadaver fracture model. METHODS Six matched pairs of fresh-frozen human cadaver wrists complete from the proximal forearm to the metacarpal bones were prepared to simulate standardized 3-part intra-articular and severe comminuted fractures. Specimens were fixed using the volar plating system with or without 2 radial styloid screws. Each specimen was loaded at a constant rate of 20 mm/min to failure. Load data was recorded and, ultimate strength and change in gap between distal and proximal fragments were measured. Data for ultimate strength and screw failure after failure loading were compared between the 2 groups. RESULTS The average ultimate strength at failure of the volar plate fixation with radial styloid screws (913.5 ± 157.1 N) was significantly higher than that without them (682.2 ± 118.6 N). After failure loading, the average change in gap between the ulnar and proximal fragment was greater than that between the radial and proximal fragment. The number of bent or broken screws in ulnar fragment was higher than that in radial fragment. The number of specimens with bent or broken screws in cases with radial styloid screws was fewer than that in the fixation without radial styloid screws group. CONCLUSION The ulnar fragment is more intensively stressed than the radial fragment under axial loading of distal radius at full wrist extension. The radial styloid screws were effective in stable volar plate fixation of distal radial fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique

BACKGROUND A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. METHODS Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were fol...

متن کامل

Distal radius volar rim plate: Technical and radiographic considerations

AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS ...

متن کامل

Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.

BACKGROUND Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatme...

متن کامل

Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model.

PURPOSE To test the hypothesis that combining orthogonal fragment-specific fixation with volar fixed-angle fixation provides markedly higher interfragment stability and construct strength compared with volar fixed-angle fixation alone. METHODS Eight matched pairs of fresh cadaveric hand and forearm specimens were potted upright in cement. Flexor and extensor tendons were isolated at insertion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2010