A calibration system for electric power at frequencies up to 1 MHz
نویسندگان
چکیده
Electrical power measurements are a central part of society today. Traditional power measurements have been focused on the power delivered by the 50 Hz or 60 Hz electrical grid with up to about 50 harmonics. This means that the bandwidth of such a power meter only needs to be a few kHz. Most modern electrical devices and machines are powered by batteries, or by the grid via DC converters. Ironically, measuring power in these devices requires higher bandwidth, because most modern devices use switching power converters, either to convert AC grid power to DC power, or to convert between different DC voltage levels. These power converters work at switching frequencies of several kHz up to several tens of kHz. Higher frequencies means potentially lower power losses, so the trend is towards higher frequencies. Many instrument manufacturers now offer power meters with bandwidth in the MHz range. In order to address the calibration needs for these instruments, we have developed a reference power calibration system for frequencies up to 1 MHz. In this article we describe the system and the procedures for ensuring traceable power measurements.
منابع مشابه
Long-Term Stability of the NIST Standard Ultrasonic Source
The National Institute of Standards and Technology (NIST) Standard Ultrasonic Source (SUS) is a system comprising a transducer capable of output power levels up to 1 W at multiple frequencies between 1 MHz and 30 MHz, and an electrical impedance-matching network that allows the system to be driven by a conventional 50 Ω rf (radio-frequency) source. It is designed to allow interlaboratory replic...
متن کاملHigh Power CW Wattmeter Calibration at NIST
The National Institute of Standards and Technology has established a measurement capability to support high power systems and devices. The automated wattmeter calibration system operates at power levels of 1 to 1000 W for frequencies from 1 to 30 MHz and 1 to 500 W from 30 to 400 MHz. A cascaded coupler technique is used to extend power measurements to high levels which are traccable to a 10 mW...
متن کاملMeasurement method of AC current up to 1 MHz
Wideband current transducers with a voltage output are often used to measure AC currents at frequencies up to 1 MHz. The ratio of output voltage to primary current as a function of frequency is the calibration result of these transducers. A traceable method to measure 1 A alternating current at frequencies of 100 kHz and 1 MHz is reported in this paper. The ratio of the wideband current transdu...
متن کاملThe Effect of Distributed Parameters on Conducted EMI from DC-Fed Motor Drive Systems in Electric Vehicles
The large dv/dt and di/dt outputs of power devices in DC-fed motor drive systems in electric vehicles (EVs) always introduce conducted electromagnetic interference (EMI) emissions and may lead to motor drive system energy transmission losses. The effect of distributed parameters on conducted EMI from the DC-fed high voltage motor drive systems in EVs is studied. A complete test for conducted EM...
متن کاملReliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants
Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...