Comparison of exercise performance in patients with chronic severe heart failure versus left ventricular assist devices.
نویسندگان
چکیده
BACKGROUND Left ventricular assist devices (LVADs) are frequently used as a bridge to cardiac transplantation and may be useful as long-term therapy. The purpose of this study was to compare the exercise performance of LVAD patients with that of ambulatory heart failure patients. METHODS AND RESULTS Exercise testing with hemodynamic and respiratory gas measurements was performed in 65 congestive heart failure (CHF) patients (age 53+/-10 years) and 20 LVAD patients (age 49+/-8 years). Peak Vo2 was significantly higher in the LVAD than the CHF patients (CHF, 12+/-3; LVAD, 15. 9+/-3.8 mL . kg-1 . min-1; P<0.001), as was the Vo2 at the anaerobic threshold (CHF, 8.1+/-2.1; LVAD, 12.2+/-2.9 mL . kg-1 . min-1; P<0.001). At rest, mean arterial blood pressure (CHF, 87+/-11; LVAD, 94+/-9 mm Hg) and cardiac output (CHF, 4+/-1; LVAD, 4. 9+/-0.9 L/min) were increased, whereas mean pulmonary artery pressure (CHF, 28+/-11; LVAD, 18+/-4 mm Hg) and pulmonary artery wedge pressure (CHF, 16+/-10; LVAD 5+/-3 mm Hg) were reduced (all P<0.01). At peak exercise, heart rate (CHF,125+/-24; LVAD, 148+/-24 bpm), blood pressure (CHF, 87+/-14; LVAD,96+/-12 mm Hg), and cardiac output (CHF, 7.6+/-2.2; LVAD, 11.2+/-2.6 L/min) were higher (all P<0. 01), whereas mean pulmonary artery pressure (CHF, 48+/-12; LVAD, 30+/-5 mm Hg) and mean pulmonary capillary wedge pressure (CHF, 31+/-11; LVAD, 14+/-6 mm Hg) were lower in the LVAD group (both P<0. 001). In the LVAD patients, Fick cardiac output was higher than LVAD flow sensor value measurements (Fick, 11.6+/-2.5; LVAD, 8.1+/-1.2 L/min; P<0.001). CONCLUSIONS Hemodynamic measurements at rest and during exercise are significantly improved in patients with devices compared with those in ambulatory heart failure patients awaiting cardiac transplantation. Similarly, the exercise capacity of device patients is better than that of transplant candidates and in the majority of patients is similar to that of patients with mild CHF.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملHemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.
BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملComparison of Left Ventricular Structure in Young Qazvin’s Elite Male Basketball Players and Non-Athletes
Performance of heart has substantial role in breaking records of sports. Achieving to optimal performance of endurance Training builds upon the consistency in several parts of body specially heart. Type, intensity, term training programs is determining components of providing structural consistency and performance of heart especially in left ventricular. Aim of this research was comparing struc...
متن کاملComparison of permanent left ventricular and biventricular pacing in patients with heart failure and chronic atrial fibrillation: prospective haemodynamic study.
OBJECTIVE To compare clinical and haemodynamic variables between left ventricular and biventricular pacing in patients with severe heart failure; and to analyse haemodynamic changes during daily life and maximum exercise during chronic left ventricular and biventricular pacing. DESIGN Prospective single blinded randomised study with crossover. SETTING University hospital (tertiary referral ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 98 12 شماره
صفحات -
تاریخ انتشار 1998