Frequency response of variable orifice type peak flow meters: requirements and testing.
نویسندگان
چکیده
Little is known about the response of variable orifice peak flow meters to high frequency flow input. The purpose of this study was to define and test dynamic requirements for such peak flow meters. In a population sample we measured peak expiratory flow (PEF), rise time (tr), from 10-90% PEF and the duration of the flow in excess of 97.5, 95 and 90% of PEF, by use of a carefully calibrated Fleisch pneumotachograph with known and adequate frequency response. Three peak flow meters (Mini Wright, Vitalograph and Ferraris) were tested with an explosive decompression calibrator adjusted to values for PEF and tr as close as possible to the 95th and 5th percentile values, respectively, both for males and females, and with peak durations between 5 and more than 100 ms. The 95th percentile values of PEF were 597 L.min-1 for females and 894 L.min-1 for males. The 5th percentile values of tr were, respectively 55 and 45 ms. The duration of flow in excess of 95% PEF was longer than 10 ms in 99% of the subjects. For all meters, the deviation of PEF corrected for alinearity were less than 5% at a peak duration of 10 ms. We conclude that PEF, rise time, and peak duration can be used for description of dynamic properties of variable orifice meters, and that the tested meters had a satisfactory frequency response for recording PEF in mostly normal subjects.
منابع مشابه
Portable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.
Little is known about the linearity of portable peak flow meters, or about physical gas factors affecting peak expiratory flow (PEF) readings. We therefore tested five portable peak flow meters of three types in an altitude chamber (sea level to 5,500 m) and in a climate chamber at sea level (7-37 degrees C) to determine the influence of the physical conditions of the gas on the reading of the ...
متن کاملRESPIRATORY PHYSIOLOGY Inadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device
Background: Recent evidence suggests that the frequency response requirements for peak expiratory flow (PEF) meters are higher than was first thought and that the American Thoracic Society (ATS) waveforms to test PEF meters may not be adequate for the purpose. Methods: The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters ...
متن کاملInadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device.
BACKGROUND Recent evidence suggests that the frequency response requirements for peak expiratory flow (PEF) meters are higher than was first thought and that the American Thoracic Society (ATS) waveforms to test PEF meters may not be adequate for the purpose. METHODS The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters ...
متن کاملPeak expiratory flow: conclusions and recommendations of a Working Party of the European Respiratory Society.
The use of peak flow meters has been widely adopted for monitoring patients with asthma. The Working Party of the European Respiratory Society (ERS) has solely addressed technical and physiological issues relating to peak expiratory flow (PEF) (flow describes the rate of change of volume (volume rate), so that flow rate is equivalent to volume acceleration. Hence, PEF should be used in preferen...
متن کاملImpact of correcting peak flow for nonlinear errors on air pollutant effect estimates from a panel study.
Air pollutant effects are commonly investigated using panel studies employing daily measurement of changes in peak expiratory flow (PEF). Variable orifice PEF meters are inaccurate with a nonlinear relationship to actual PEF. The impact on a panel study of correcting these errors was examined. Twice-daily PEF readings were taken by 147 9-yr old children for 8 weeks and corrected using an equati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 8 5 شماره
صفحات -
تاریخ انتشار 1995