Usefulness of medium-energy collimator for sentinel node lymphoscintigraphy imaging in breast cancer patients.

نویسندگان

  • Hiroyuki Tsushima
  • Teruhiko Takayama
  • Takashi Yamanaga
  • Hiroto Kizu
  • Yoshihiro Shimonishi
  • Kazuhisa Kosakai
  • Atsushi Noguchi
  • Masahisa Onoguchi
چکیده

UNLABELLED This study was performed to investigate the usefulness of a general-purpose medium-energy (ME) collimator for the accurate localization of the sentinel lymph node (SLN) in breast cancer patients. METHODS We compared phantom images and lymphoscintigraphy images obtained under different conditions for a patient with breast cancer. Comparisons were performed between 2 cameras, between a low-energy high-resolution (LEHR) collimator and a general-purpose ME collimator, and between energy windows centered at 141 keV and at 146 keV. Profile curves and image contrast were evaluated along with the visual interpretation of images. The most suitable imaging time was selected from the relationship between contrast and the data acquisition time. RESULTS The images obtained with the general-purpose ME collimator and the energy window centered at 141 keV were of poorer quality than those obtained with the LEHR collimator and the same energy window. However, the quality of the images obtained with the general-purpose ME collimator improved when the energy window was centered at 146 keV. The method involving the general-purpose ME collimator and the energy window centered at 146 keV showed excellent image quality similar to that obtained with the LEHR collimator. The enhancement of contrast was confirmed at more than 3 cm away from the center of the injection site. Stable contrast was obtained with a data acquisition time of 5 min, with the general-purpose ME collimator, and with the energy window centered at 146 keV. CONCLUSION The method involving the general-purpose ME collimator and the energy window centered at 146 keV has the merit of the lymph node not being concealed by a lead shield. This new method is expected to improve the rate of detection of SLN and has the potential for shortening the acquisition time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

Dynamic lymphoscintigraphy in breast cancer patients: feasibility and added value

Introduction: Lymphoscintigraphy is imaging of the lymphatic system and has been integrated into the sentinel node mapping procedures. Lymphoscintigraphy usually encompasses early or delayed static images. However, immediate dynamic imaging of the lymphatic basins and tumors has also been used as an adjunct lymphoscintigraphy imaging. The aim of this study was ...

متن کامل

Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients

Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...

متن کامل

Efficacy of high-energy collimator for sentinel node lymphoscintigraphy of early breast cancer patients

INTRODUCTION Lymphoscintigraphy is an important part of sentinel node mapping in breast cancer patients. Sometimes star shaped artefacts due to septal penetration can be problematic during imaging. In the current study, we evaluated the possibility of high energy (HE) collimators use for lymphoscintigraphy. PATIENTS AND METHODS Twenty patients with early breast carcinoma were included. Thirty...

متن کامل

Inappropriate cervical injection of radiotracer for sentinel node mapping in a uterine cervix cancer patient: importance of lymphoscintigraphy and blue dye injection

Herein, we report a case of sentinel lymph node mapping in a uterine cervix cancer patient, referring to the nuclear medicine department of our institute. Lymphoscintigraphy images showed inappropriate intra‐cervical injection of radiotracer. Blue dye technique was applied for sentinel lymph node mapping, using intra‐cervical injection of methylene blue. Two blue/cold sentinel lymph nodes, with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2006