Does size matter? Separations on guard columns for fast sample analysis applied to bioenergy research

نویسندگان

  • Stefan Bauer
  • Ana B. Ibáñez
چکیده

BACKGROUND Increasing sample throughput is needed when large numbers of samples have to be processed. In chromatography, one strategy is to reduce column length for decreased analysis time. Therefore, the feasibility of analyzing samples simply on a guard column was explored using refractive index and ultraviolet detection. Results from the guard columns were compared to the analyses using the standard 300 mm Aminex HPX-87H column which is widely applied to the analysis of samples from many biotechnology- and bioenergy-related experiments such as biomass conversions or fermentations. RESULTS The 50 mm Rezex RFQ Fast Acid H(+) guard column was able to separate the most common fermentation products (ethanol, acetone, iso- and n-butanol) and promising precursors (furfural and 5-hydroxymethylfurfural) of biofuels and value-added chemicals. Compound profiles in fermentation samples were analyzed with similar accuracy compared to results using the 300 mm column. However, separation of glucose and xylose was not achieved. Nevertheless, it was possible to monitor the consumption of one of the two sugars during fermentation if the other one was absent or remained constant over the course of the experiment. If correct peak integration and interference subtraction was applied, concentration profiles from enzymatic digestibility experiments and even more complex samples (e.g. acetone-butanol-ethanol (ABE) fermentation) were reliably obtained. With the 50 mm guard column, samples were analyzed up to ten-times faster compared to the 300 mm column. A further decrease in analysis time was achieved by using the 30 mm Micro Guard Cation H guard column. This column is especially suitable for the rapid analysis of compounds with long elution times on the standard 300 mm column, such as biofuel-related alcohols (e.g., n-butanol, n-hexanol) and furan- and tetrahydrofuran-type molecules. CONCLUSION Applied to a suitable set of samples, separations on a guard column can give rapid and sufficiently accurate information on compound changes over the course of an experiment. Therefore, it is an inexpensive and ideal tool for processing a large amount of samples, such as in screening or discovery experiments, where detecting relative changes is often sufficient to identify promising candidates for further analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical considerations in the use of "high-performance" liquid chromatography in therapeutic drug monitoring.

I review the methodology of "high-performance" liquid chromatography as applied to therapeutic drug monitoring. Aside from direct injection of sample, sample cleanup involves miscible and immiscible organic solvent extractions, solid-phase extraction, and size separations. Column considerations are bonded phases, column dimensions, particle size, guard columns, stability, pH range, and reproduc...

متن کامل

Gas Chromatography

Capillary GC Columns and Guard Columns/ Retention Gaps 2 How to Choose a Column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Columns by Phase Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ionic Liquid Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MS-Grade Columns . . . . . ...

متن کامل

Ion Mobility Mass Spectrometry

for more complex analysers for automated sample processing and plant control. The separation time will continue to decrease; in the past there has been limited interest in fast separations but this could change as automated sample processing is developed. Increasing use of coupled techniques such as GC-GC, liquid chromatography-GC, and supercritical Suid chromatography-GC for the separation of ...

متن کامل

Numerical Formulation on Crack Closing Effect In Buckling Analysis of Edge-Cracked Columns

In this paper, buckling of simply supported column with an edge crack is investigated numerically and analytically. Four different scenarios of damage severities are applied to a column, open crack assumption and the effect of closing crack in stability of the column which depends on position and size of cracks, are numerically compared. Crack surfaces contact is modeled with GAP element using ...

متن کامل

Determining the Sample size for Estimation of the CCC-R Control Chart Parameters Based on Estimation Costs

In today's highly competitive industrial environment due to fast technology development, quality practitioners will to detect out-of-control situations and take actions whenever is necessary as soon as possible. Accordingly, new statistical procedures have been enhanced incessantly both to handle high yield processes along with looking for methods of minimizing all quality cost. CCC-r chart, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015