Horseradish peroxidase-catalyzed synthesis of poly(thiophene-3-boronic acid) biocomposites for mono-/bi-enzyme immobilization and amperometric biosensing.

نویسندگان

  • Yi Huang
  • Wen Wang
  • Zou Li
  • Xiaoli Qin
  • Lijuan Bu
  • Zhiyong Tang
  • Yingchun Fu
  • Ming Ma
  • Qingji Xie
  • Shouzhuo Yao
  • Jiming Hu
چکیده

We report here on a facile enzymatic polymerization protocol to prepare enzyme-poly(thiophene-3-boronic acid) (PTBA) polymeric biocomposites (PBCs) for high-performance mono-/bi-enzyme amperometric biosensing. Horseradish peroxidase (HRP)-catalyzed polymerization of thiophene-3-boronic acid (TBA) monomer was conducted in aqueous solution containing HRP (or plus glucose oxidase (GOx)) by either directly added or GOx-glucose generated oxidant H2O2. The mono-/bi-enzyme amperometric biosensors were prepared simply by casting the dialysis-isolated PBCs on Au-plated Au electrode (Auplate/Au), followed by coating with an outer-layer chitosan (CS) film. The boronic acid residues are capable of covalent bonding with enzyme at the glycosyl sites (boronic acid-diols interaction), which should less affect the enzymatic activity as compared with the common cases of covalent bonding at the peptide chains, and UV-vis spectrophotometric tests confirmed that the encapsulated HRP almost possesses its pristine enzymatic specific activity. The enzyme electrodes were studied by cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry in the presence of Fe(CN)6(4-) mediator. The CS/HRP-PTBA/Auplate/Au electrode responded linearly to H2O2 concentration from 1 to 300 μM with a sensitivity of 390 μA mM(-1)cm(-2) and a limit of detection (LOD) of 0.1 μM. The bienzyme CS/GOx-HRP-PTBA(H2O2)/Auplate/Au electrode responded linearly to glucose concentration from 5 μM to 0.83 mM with a sensitivity of 75.1 μA mM(-1)cm(-2) and a LOD of 1 μM, and it is found here that the use of Fe(CN)6(4-) that can only efficiently mediate HRP favorably avoids the "unusual amperometric responses" observed when other mediators that can efficiently turn over both HRP and GOx are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Amperometric Hydrogen Peroxide Sensor Based on Horseradish Peroxidase-Immobilized Poly(Thiophene-co-EpoxyThiophene)

A modified electrode for hydrogen peroxide (H₂O₂) sensing was prepared via thiophene (Th) with epoxy group. Thiophene (EpoxyTh) with epoxy group was synthesized by reaction of 3-bromothiophene and glycidyl methacrylate (GMA) in acetonitrile according to Heck Reaction. The electrocopolymerization of Th and EpoxyTh was performed on the surface of indium tin oxide (ITO) electrode by cycling the po...

متن کامل

Functionalization of electrode surfaces with three-dimensional networks of electropolymerized gold nanoparticles for biosensor design

Nowaday, the construction of new electrochemical biosensors with improved bioanalytical performance and robustness is directly linked to the development of novel strategies for tailormade design of electrode surfaces. Such strategies should provide electrical interfaces with nanoor microsized tree-dimensional topology that allow the successful and stable immobilisation of the biomolecules witho...

متن کامل

Nanostructured FeS as a mimic peroxidase for biocatalysis and biosensing.

Artificial enzyme mimics have attracted considerable interest due to easy denaturation and leakage of enzymes during their storage and immobilization procedure. Herein we describe the design of a novel mimic peroxidase, a nanostructure of sheet-like FeS prepared by a simple micelle-assisted synthetic method. Such a nanostructure has a large specific surface area and high peroxidase-like activit...

متن کامل

An Amperometric Biosensor Utilizing a Ferrocene-Mediated Horseradish Peroxidase Reaction for the Determination of Capsaicin (Chili Hotness)

Chili hotness is very much dependent on the concentration of capsaicin present in the chili fruit. A new biosensor based on a horseradish peroxidase enzyme-capsaicin reaction mediated by ferrocene has been successfully developed for the amperometric determination of chili hotness. The amperometric biosensor is fabricated based on a single-step immobilization of both ferrocene and horseradish pe...

متن کامل

Enzyme immobilization on poly(ethylene-co-acrylic acid) films studied by quartz crystal microbalance with dissipation monitoring.

In this study, we use the quartz crystal microbalance with dissipation monitoring (QCM-D) to study the immobilization of the enzyme horseradish peroxidase (HRP) on poly(ethylene-co-acrylic acid) (PEAA) films. The surface polarity of spin-coated PEAA films was varied by heat treatments in air or in a 30% NaOH aqueous solution leading to COOH-depleted or COOH-enriched surfaces, respectively. Two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2013