Ambient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
نویسندگان
چکیده
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high temperatures. The test parameters covered in this experimental program were the load eccentricity (0, 20 and 50 mm) and the type of infill (plain concrete or bar-reinforced concrete). Six room temperature tests were performed, while other six tests were carried out at elevated temperatures, under both concentric and eccentric axial load. Using the results of these tests, the current provisions of Eurocode 4 for room temperature and fire design were assessed, and a specific design proposal developed by the authors was evaluated.
منابع مشابه
Fire behavior of axially loaded slender high strength concrete - filled tubular columns
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns ...
متن کاملBehavior of FRP-Confined Reactive Powder Concrete Columns under Eccentric Loading
Fiber reinforced Polymers (FRP) have widely used for the purposes of enhances strength and ductility of concrete columns. Proper design of such hybrid columns, however, requires a better recognition of the behavior of concrete columns confined with FRP. In this paper, the influence of FRP thickness, concrete compressive strength, and column size on the performance of eccentrically loaded reacti...
متن کاملInvestigating of the Effect of Concrete Confinement on the Axial Performance of Circular Concrete Filled Double-Skin Steel Tubular (CFDST) Long Columns
In this study, the co-operation of steel and concrete in composite columns is considered. Using numerical modeling to study the behavior of these sections, a new type of sections, namely Concrete Filled Double-Skin steel Tubular (CFDST) columns, is introduced. The parameters and techniques that influence the numerical simulation that bring this modeling closer to...
متن کاملExperimental Study on Performance of Fiber Concrete-filled Tube Columns under Axial Loading
There have been great developments in the area of civil engineering in the recent few decades and among these, construction and material innovation are quite prominent. Steel-concrete composite construction has emerged as one of the fastest methods of construction. Even though considerable research efforts on conventional reinforced concrete columns have been executed prior to now, concrete fil...
متن کاملInelastic Behavior of Concrete-filled Thin-walled Steel Tubular Columns Subjected to Local Buckling
This paper is concerned with the inelastic behavior of axially loaded concrete-filled thin-walled steel tubular columns subjected to local buckling. A nonlinear fiber element analysis program accounting for local buckling effects is developed for predicting the ultimate strength and ductility of concrete-filled thin-walled steel tubular columns. The effects of local buckling are taken into cons...
متن کامل