The Need of Slanted Side Holes for Venous Cannulae

نویسنده

  • Joong Yull Park
چکیده

Well-designed cannulae must allow good flow rate and minimize nonphysiologic load. Venous cannulae generally have side holes to prevent the rupture of blood vessel during perfusion. Optimizing side hole angle will yield more efficient and safe venous cannulae. A numerical modeling was used to study the effect of the angle (0°-45°) and number (0-12) of side holes on the performance of cannulae. By only slanting the side holes, it increases the flow rate up to 6% (in our models). In addition, it was found that increasing the number of side holes reduces the shear rate up to 12% (in our models). A new parameter called "penetration depth" was introduced to describe the interfering effect of stream jets from side holes, and the result showed that the 45°-slanted side holes caused minimum interfering for the flow in cannula. Our quantitative hemodynamic analysis study provides important guidelines for venous cannulae design.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Simulation of Side-Pumped Slanted Faces of High Power Yb:YAGYAG Thin-Disk Laser

We present a novel slanted faces of thin-disk composite Yb:YAG YAG laser which is side-pumped by four non-symmetric hollow- ducts. The pump light distribution in the disk is modeled by using Monte-Carlo ray tracing method. The temperature distribution inside the crystal is calculated by taking into account either the concentration of Yb+3 ion or the different transmission of laser output coupl...

متن کامل

The evaluation of slant hole collimator in myocardial perfusion SPECT: a simulation study

Introduction: We have investigated cardiac SPECT with slant hole collimator in which the holes are slanted towards the target organ, to provide greater sensitivity over the parallel hole collimator. In addition, parallel hole collimator was used to obtain a comparison in FWHM, sensitivity, Compton and photoelectric area values in the simulations. Materials and Methods...

متن کامل

A single-center experience with luminal venous cannulae obstruction caused by clot formation during bypass.

Our institution experienced two bypass cases from January through December 2011 in which venous return was significantly variable and at times poor. Luminal clot formation in the venous cannulae was found in each case postbypass. These events were captured and monitored through our institution's Non-Routine Event Reporting Program and eventually reported to the Food and Drug Administration (FDA...

متن کامل

Late perforation by central venous cannulae.

Three cases of hydrothorax secondary to late perforation of the superior vena cava by central venous cannulae are presented. The care of central venous cannulae is discussed.

متن کامل

A survey of the use of ultrasound guidance in internal jugular venous cannulation.

It has been that suggested the use of two dimensional (2D) ultrasound to facilitate placement of central venous cannulae in the internal jugular vein improves patient safety and reduces complications. Since the introduction of the National Institute for Clinical Excellence Technology Appraisal Guideline Number 49 in 2002, promoting the use of ultrasound in placement of internal jugular venous c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012