Determination of APTT factor sensitivity – the misguiding guideline

نویسندگان

  • A S Lawrie
  • S Kitchen
  • M Efthymiou
  • I J Mackie
  • S J Machin
چکیده

INTRODUCTION The Clinical and Laboratory Standards Institute (CLSI) has produced a guideline detailing how to determine the activated partial thromboplastin time's (APTT) sensitivity to clotting factor deficiencies, by mixing normal and deficient plasmas. Using the guideline, we determined the factor sensitivity of two APTT reagents. METHODS APTTs were performed using Actin FS and Actin FSL on a Sysmex CS-5100 analyser. The quality of factor-deficient and reference plasmas from three commercial sources was assessed by assaying each of the clotting factors within the plasmas and by performing thrombin generation tests (TGT). RESULTS Testing samples from 50 normal healthy subjects gave a two-standard deviation range of 21.8-29.2 s for Actin FS and 23.5-29.3 s for Actin FSL. The upper limits of these ranges were subsequently used to determine APTT factor sensitivity. Assay of factor levels within the deficient plasmas demonstrated that they were specifically deficient in a single factor, with most other factors in the range 50-150 iu/dL (Technoclone factor VII-deficient plasma has 26 iu/dL factor IX). APTTs performed on mixtures of normal and deficient plasmas gave diverse sensitivity to factor deficiencies dependent on the sources of deficient plasma. TGT studies on the deficient plasmas revealed that the potential to generate thrombin was not solely associated with the levels of their component clotting factors. CONCLUSION Determination of APTT factor sensitivity in accordance with the CLSI guideline can give inconsistent and misleading results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do PT and APTT sensitivities to factors' deficiencies calculated by the H47-A2 2008 CLSI guideline reflect the deficiencies found in plasmas from patients?

INTRODUCTION Prothrombin time (PT) and activated partial thromboplastin time (APTT) sensitivity for detecting isolated factor deficiencies varies with different reagents and coagulometers. The Clinical and Laboratory Standards Institute (CLSI) H47A2 guideline proposed a method to calculate these sensitivities, but some inconsistency has been reported. This study aimed to calculate factor sensit...

متن کامل

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....

متن کامل

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....

متن کامل

One-step chromogenic equivalent of activated partial thromboplastin time evaluated for clinical application.

We evaluated the clinical usefulness of a recently developed semi-automated one-step chromogenic equivalent of activated partial thromboplastin time (APTT; Behring). This simple test is easily adaptable for automation. Generally, the results with this chromogenic one-step APTT were at least as precise as those obtained with comparative coagulometric methods. The chromogenic one-step APTT showed...

متن کامل

Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor

A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals. Due to its highly sensitivity, real time detection and low cost, the proposed QCM biosensor has a promising potential in blood coagulation research. In the current study, the QCM biosensor was used to determin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2013