چکیده

BACKGROUND Spinal cord stimulation (SCS) has been successfully used to treat chronic intractable pain for over 40 years. Successful clinical application of SCS is presumed to be generally dependent on maximizing paresthesia-pain overlap; critical to achieving this is positioning of the stimulation field at the physiologic midline. Recently, the necessity of paresthesia for achieving effective relief in SCS has been challenged by the introduction of 10 kHz paresthesia-free stimulation. In a large, prospective, randomized controlled pivotal trial, HF10 therapy was demonstrated to be statistically and clinically superior to paresthesia-based SCS in the treatment of severe chronic low back and leg pain. HF10 therapy, unlike traditional paresthesia-based SCS, requires no paresthesia to be experienced by the patient, nor does it require paresthesia mapping at any point during lead implant or post-operative programming. OBJECTIVES To determine if pain relief was related to technical factors of paresthesia, we measured and analyzed the paresthesia responses of patients successfully using HF10 therapy. STUDY DESIGN Prospective, multicenter, non-randomized, non-controlled interventional study. SETTING Outpatient pain clinic at 10 centers across the US and Italy. METHODS Patients with both back and leg pain already implanted with an HF10 therapy device for up to 24 months were included in this multicenter study. Patients provided pain scores prior to and after using HF10 therapy. Each patient's most efficacious HF10 therapy stimulation program was temporarily modified to a low frequency (LF; 60 Hz), wide pulse width (~470 mus), paresthesia-generating program. On a human body diagram, patients drew the locations of their chronic intractable pain and, with the modified program activated, all regions where they experienced LF paresthesia. Paresthesia and pain drawings were then analyzed to estimate the correlation of pain relief outcomes to overlap of pain by paresthesia, and the mediolateral distribution of paresthesia (as a surrogate of physiologic midline lead positioning). RESULTS A total of 61 patients participated across 11 centers. Twenty-eight men and 33 women with a mean age of 56 ± 12 years of age participated in the study. The average duration of implantable pulse generator (IPG) implant was 19 ± 9 months. The average predominant pain score, as measured on a 0 - 10 visual analog scale (VAS), prior to HF10 therapy was 7.8 ± 1.3 and at time of testing was 2.5 ± 2.1, yielding an average pain relief of 70 ± 24%. For all patients, the mean paresthesia coverage of pain was 21 ± 28%, with 43% of patients having zero paresthesia coverage of pain. Analysis revealed no correlation between percentage of LF paresthesia overlap of predominant pain and HF10 therapy efficacy (P = 0.56). Exact mediolateral positioning of the stimulation electrodes was not found to be a statistically significant predictor of pain relief outcomes. LIMITATIONS Non-randomized/non-controlled study design; short-term evaluation; certain technical factors not investigated. CONCLUSION Both paresthesia concordance with pain and precise midline positioning of the stimulation contacts appear to be inconsequential technical factors for successful HF10 therapy application. These results suggest that HF10 therapy is not only paresthesia-free, but may be paresthesia-independent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Frequency Spinal Cord Stimulation at 10 kHz for the Treatment of Chronic Pain: 6-Month Australian Clinical Experience.

BACKGROUND High frequency spinal cord stimulation at 10 kHz (HF10 therapy) represents a prominent advance in spinal cord stimulation (SCS) therapy, having demonstrated enhanced efficacy in patients with back and leg pain and pain relief without paresthesia that is sustained at 24 months post implant. OBJECTIVE To report on the effectiveness HF10 SCS therapy for a wide range of intractable pai...

متن کامل

Cervical spinal cord stimulation: an analysis of 23 patients with long-term follow-up.

BACKGROUND For more than 3 decades, spinal cord stimulation has successfully been employed to treat neuropathic pain. Cervical spinal cord stimulation, despite now being standard in many hospitals, has only rarely been subjected to a critical review within the literature. OBJECTIVES The aim of this study was to determine the efficacy of cervical spinal cord stimulation (SCS) in a representati...

متن کامل

Improved Pain Relief With Burst Spinal Cord Stimulation for Two Weeks in Patients Using Tonic Stimulation: Results From a Small Clinical Study

OBJECTIVES Conventional spinal cord stimulation (SCS) delivers a tonic waveform with consistent stream of pulses; burst delivers groups of pulses separated by short pulse-free periods. The current study compared the short-term safety and efficacy of burst with tonic stimulation in subjects already receiving SCS. MATERIALS AND METHODS At 4 IRB-approved sites, 22 subjects previously implanted w...

متن کامل

Automatic adaptation of neurostimulation therapy in response to changes in patient position: results of the Posture Responsive Spinal Cord Stimulation (PRS) Research Study.

BACKGROUND Variation in the intensity of neurostimulation with body position is a practical problem for many patients implanted with a spinal cord stimulation system because positional changes may result in overstimulation or understimulation. These posture-related changes in patients' perception of paresthesia can affect therapeutic outcomes of spinal cord stimulation therapy. An accelerometer...

متن کامل

Pulse width programming in spinal cord stimulation: a clinical study.

BACKGROUND With advances in spinal cord stimulation (SCS) technology, particularly rechargeable implantable, patients are now being offered a wider range of parameters to treat their pain. In particular, pulse width (PW) programming ranges of rechargeable implantable pulse generators now match that of radiofrequency systems (with programmability up to 1000 microseconds. The intent of the presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain physician

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2017