Pii: S1388-2457(99)00258-8

نویسندگان

  • L. K. McEvoy
  • M. E. Smith
  • A. Gevins
چکیده

Objective: Task-related EEG is sensitive to changes in cognitive state produced by increased task dif®culty and by transient impairment. If task-related EEG has high test±retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). Methods: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test±retest interval of ,1 h) and between session (test±retest interval of ,7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. Results: Task-related EEG was highly reliable within and between sessions (r . 0.9 for all components in WM task, and r . 0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r . 0.7 for all 4 components). Conclusions: These results suggest that under appropriate conditions, task-related EEG has suf®cient retest reliability for use in assessing clinical changes in cognitive status. q 2000 Elsevier Science Ireland Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1388-2457(99)00005-x

About two-thirds of epilepsy patients who learn to control their slow cortical potential shifts (SCP) reduce their seizure rate, but the remaining third does not demonstrate clinical improvement. In the present study, this ®nding was replicated in a group of 27 patients with focal epilepsy. We found that patients who consistently produced larger negative SCP in all conditions during the ®rst ph...

متن کامل

Pii: S1388-2457(99)00172-8

Objective and methods: Sixteen polysomnographic recordings from 8 European sleep laboratories were analyzed. The histogram analysis was used to introduce quality control of all-night EEG recordings. Results: It was found that the header information does not always provide the real saturation values of the recording equipment. The entropy measure was used for the quantitative analysis of the dyn...

متن کامل

Pii: S1388-2457(99)00052-8

Objectives: An event-related brain potential (ERP) study investigated whether spatially selective processing in vision and audition is controlled by a single supramodal system or by independent modality-speci®c systems. Methods: Event-related brain potentials were recorded in response to visual and auditory stimuli at attended and unattended locations. In the `Attend Same' condition, attention ...

متن کامل

Pii: S1388-2457(00)00527-7

Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10±20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is desc...

متن کامل

Pii: S1388-2457(02)00297-3

For algorithm developers, this review details recent approaches to the problem, compares the accuracy of various algorithms, identifies common testing issues and proposes some solutions. For the algorithm user, e.g. electroencephalograph (EEG) technician or neurologist, this review provides an estimate of algorithm accuracy and comparison to that of human experts. Manuscripts dated from 1975 ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000