Comparison of the MicroScan system with the API Staph-Ident system for species identification of coagulase-negative staphylococci.
نویسندگان
چکیده
To evaluate the accuracy of the MicroScan System (American Hospital Supply Corp., Sacramento, Calif.) for identification of coagulase-negative staphylococci, we tested 175 clinical isolates of coagulase-negative staphylococci. The results obtained by the MicroScan system were compared with those of the API Staph-Ident system (Analytab Products, Plainview, N.Y.). Forty-three discrepancies between the two systems were resolved by the conventional method of Kloos and Schleifer (W.E. Kloos and K.H. Schleifer, J. Clin. Microbiol. 1:82-88, 1975). The MicroScan and the Staph-Ident systems correctly identified 146 (86.4%) and 154 (88%) of 175 strains, respectively. The API system failed to identify phosphatase-negative Staphylococcus epidermidis. The MicroScan system demonstrated the greatest accuracy in the identification of S. epidermidis and S. saprophyticus, whereas lesser accuracy was achieved with S. hominis, S. warneri, and S. sciuri.
منابع مشابه
Reproducibility of API Staph-Ident system identifications of coagulase-negative staphylococci isolated from blood.
Fifty-five isolates of coagulase-negative staphylococci from blood were identified four times each by using the API Staph-Ident (API-SI) system to determine the identification reproducibility of the system. Identifications were determined by using both Version 1 and Version 2 of the API-SI Profile Index. The 75 to 100% reproducibility levels, including reproducible nonidentifications, were 98.2...
متن کاملIdentification of coagulase-negative staphylococci with the API STAPH-IDENT system.
A group of 300 clinically derived isolates of coagulase-negative staphylococci were tested in parallel with the API STAPH-IDENT system (Analytab Products) and 14 conventional biochemical tests contained in Kloos and Schleifer's simplified scheme for identification of human Staphylococcus species. STAPH-IDENT is a miniaturized biochemical test strip that incorporates four synthetic chromogenic s...
متن کاملClinical comparison of the AutoMicrobic system gram-positive identification card, API Staph-Ident, and conventional methods in the identification of coagulase-negative Staphylococcus spp.
In an effort to rapidly identify coagulase-negative staphylococci (CNS), a clinical comparison was conducted with the AutoMicrobic system Gram-Positive Identification Card (GPI) (Vitek Systems, Inc.), the API Staph-Ident (Analytab Products), and the conventional methods of W. E. Kloos and K. H. Schleifer (W. E. Kloos and K. H. Schleifer, J. Clin. Microbiol. 1:82-88, 1975). CNS isolates tested i...
متن کاملCharacteristics of coagulase-negative staphylococci that help differentiate these species and other members of the family Micrococcaceae.
One hundred reference strains and 1,240 clinical isolates representing 26 species of the family Micrococcaceae were used to evaluate the potential of tests for synergistic hemolysis, adherence to glass, pyroglutamyl-beta-naphthylamide hydrolysis, and susceptibility to a set of five antimicrobial agents for differentiating these species and strains within the species. Sixty-eight percent of the ...
متن کاملIdentification of Staphylococcus species of bovine origin with the API Staph-Ident system.
The API Staph-Ident system was evaluated as a means for identifying the species of bovine strains of staphylococci routinely isolated from quarter-milk samples. The species identity of 314 of 581 (54%) isolates of staphylococci was correctly determined by this method. The API Staph-Ident system was more accurate in correctly identifying Staphylococcus aureus (93.9%) than in correctly identifyin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 23 1 شماره
صفحات -
تاریخ انتشار 1986