Quantitative assessment of global and regional left ventricular function with low-contrast dose digital subtraction ventriculography.

نویسندگان

  • G B Mancini
  • J M Hodgson
  • V Legrand
  • E R Bates
  • F M Aueron
  • M T LeFree
  • J S Smith
  • G J Beauman
  • R A Vogel
چکیده

Few studies have compared the use of low-contrast dose digital subtraction ventriculography with conventional ventriculography for quantitative assessment of both global and regional left ventricular function. Accordingly, 34 patients underwent conventional ventriculography using 36 ml of ionic contrast material and digital ventriculography (mask-mode) using 10 ml of contrast diluted in 10 ml of saline and injected over two seconds. Data from two patients were excluded because of ectopy during cineventriculography and from one because of ectopy during both studies. End-diastolic and end-systolic volumes were calculated from both studies by an area-length method and used to calculate ejection fractions. Regional wall motion was quantitated by the centerline method. Results of linear regression analysis demonstrated high correlations for all parameters (end-diastolic volume, r = 0.85; end-systolic volume, r = 0.93; ejection fraction, r = 0.92; quantitative regional wall motion, r = 0.90). Thus, low-contrast dose digital subtraction ventriculography provides an accurate assessment of both global and regional ventricular function and minimizes the required dose and inherent risks of contrast media.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of left ventricular function by digital subtraction angiography.

Twenty five patients who had undergone conventional coronary arteriography and left ventriculography for suspected coronary artery disease had left ventriculography performed by digital subtraction angiography as outpatients; there were no complications requiring admission to hospital. A catheter was introduced percutaneously and positioned in the superior vena cava; 40-50 ml of contrast medium...

متن کامل

Quantitative assessment of regional left ventricular function by densitometric analysis of digital-subtraction ventriculograms: correlation with myocardial systolic shortening in dogs.

Conventional wall motion analysis of contrast ventriculograms assesses only that part of the wall that is tangential to the x-ray beam. To assess regional left ventricular function in three dimensions, a new computerized method based on densitometric analysis of digital subtraction left ventriculograms was developed and validated in nine open-chest dogs instrumented with a circumflex coronary a...

متن کامل

Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. Du...

متن کامل

Digital subtraction angiography: a review of cardiac applications.

I MAGING OF the chambers of the heart, pulmonary circulation, and great vessels by intravenous (IV) contrast injection was clinically implemented as early as 1939.’ It was not until the achievement of relatively recent advances in digital electronics, image intensification, and television technology that a major resurgence of interest in this technique occurred. These technological advances in ...

متن کامل

Assessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.

BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 87 5  شماره 

صفحات  -

تاریخ انتشار 1985