Food surface texture measurement using reflective confocal laser scanning microscopy.

نویسندگان

  • S Sheen
  • G Bao
  • P Cooke
چکیده

Confocal laser scanning microscopy (CLSM) was used in the reflection mode to characterize the surface texture (roughness) of sliced food surfaces. Sandpapers with grit size between 150 and 600 were used as height references to standardize the CLSM hardware settings. Sandpaper particle sizes were verified by scanning electron microscopy (SEM). The mean amplitude (in micrometers) of surface variation along line segments of the scanned sandpaper topographical image sets showed very close agreement between the measured result and the grit particle size (based on the U.S. Coated Abrasive Manufactures Inst. {CAMI], standard). The verified instrument settings were then used to measure the surface texture of mechanically sliced food surfaces, including cooked ham, salami, and cheese. Sliced food surface texture parameters of Ra (average height of a line segment), Rs (surface area ratio), Pa (average height on a region of interest), and Pq (root-mean-square height on a region of interest) were evaluated by this method. Values of the surface roughness of sliced ham, salami, and cheese were found to be comparable to the range of dimensions of selected sandpapers. The CLSM method may be useful for other surface texture measurements, and to investigate the impact of food surface texture on microbial adhesion or attachment, which might play a significant role in microbial transfer from one surface to another.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal and conjunctival manifestations in Fabry disease: in vivo confocal microscopy study.

PURPOSE To describe the microscopic corneal and conjunctival findings in patients with Fabry disease (FD) related keratopathy by using in vivo confocal microscopy. DESIGN Prospective observational case series. METHODS Twelve eyes of six patients affected by Fabry disease, belonging to two different families, underwent in vivo confocal microscopic examination. Corneal and conjunctival morpho...

متن کامل

Development of 3D Chromatin Texture Analysis Using Confocal Laser Scanning Microscopy

INTRODUCTION Analysis of nuclear texture features as a measure of nuclear chromatin changes has been proven to be useful when measured on thin (5-6 microm) tissue sections using conventional 2D bright field microscopy. The drawback of this approach is that most nuclei are not intact because of those thin sections. Confocal laser scanning microscopy (CLSM) allows measurements of texture in 3D re...

متن کامل

Development of 3-D chromatin texture analysis

The aim of the study described in this Chapter was to develop and implement 3-D texture features that quantitatively describe the nuclear chromatin distribution. Thirty-five features thoughtfully chosen from 4 categories of 3-D texture features (discrete texture features, Markovian features, fractal features, grey value distribution features) were selected and tested for invariance properties (...

متن کامل

A new approach to numerical characterisation of wear particle surfaces in three-dimensions for wear study

In the wear and tear process of synovial joints, wear particles generated and released from articular cartilage within the joints have different surface topology and mechanical property. Three-dimensional (3D) particle images acquired using laser scanning confocal microscopy (LSCM) contain appropriate surface information for quantitatively characterizing the surface topology and changes to seek...

متن کامل

In vivo laser confocal microscopy findings in patients with map-dot-fingerprint (epithelial basement membrane) dystrophy

BACKGROUND The purpose of this study was to investigate pathological changes of the corneal cell layer in patients with map-dot-fingerprint (epithelial basement membrane) dystrophy by in vivo laser corneal confocal microscopy. METHODS Two patients were evaluated using a cornea-specific in vivo laser scanning confocal microscope (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of food science

دوره 73 5  شماره 

صفحات  -

تاریخ انتشار 2008