Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

نویسندگان

  • I Khan
  • MY Dar
  • S Rashid
  • MF Butt
چکیده

Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1) or transverse with mildly comminuted (AO34-C2) patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the patients were treated with open reduction and internal fixation using two parallel cannulated screws and 18G stainless steel wire as per the tension band principle. Results: There were eighteen males (72%) and seven females (28%). The age group ranged from 24 to 58 years, with mean age of 38 years. The most common mode of injury was fall (72%) followed by road traffic accident (20%) and violent quadriceps contraction (8%). Transverse fracture was present in 60% and transverse fracture with mild comminution in 40% of patients. Mean time to achieve union was 10.7 weeks (range 8-12 weeks). Mean ROM at three months was 113.8 degree (90-130) and at final follow up this improved to 125.4 degrees (range 100-140). There was one case of knee stiffness and no case of implant failure was observed. Patients were evaluated using Bostman scoring, the mean score at three months being 26.04 which improved to 27.36 at the end of final follow up at one year. Conclusion: Cannulated cancellous screws with anterior tension band wiring is a safe, reliable and reproducible method in management of transverse patellar fractures, with less chances of implant failure and soft tissue irritation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate.

This biomechanical study is the first to compare 3 fixation methods-bilateral fixed-angle plate, modified anterior tension wiring, and cannulated lag screws with anterior tension wiring-in multifragmentary distal patella fractures. A T-shaped 3-part fracture simulating a multifragmentary articular distal patella fracture (AO/OTA 34-C2.2) was created in 18 human cadaver knee specimens. Three gro...

متن کامل

Comparison of a minimally invasive technique with open tension band wiring for displaced transverse patellar fractures.

BACKGROUND Open reduction and internal fixation with tension band wire is the standard treatment for displaced transverse patellar fractures. Recently, some minimally invasive techniques have been proposed as possible alternative methods. This retrospective study compared a newly reported percutaneous osteosynthesis with conventional open method for the treatment of displaced transverse patella...

متن کامل

Percutaneous Cannulated Screws with Tension Band Wiring Technique in Patella Fractures

INTRODUCTION Most patellar fractures are transverse involving the central third. Open reduction and stabilization of transverse patellar fractures is indicated if there is more than 2-3 mm of fragment separation and/or articular incongruity. SURGICAL TECHNIQUE This study describes a percutaneous 2 cannulated screws and modified tension band wiring technique to treat transverse patellar fractu...

متن کامل

Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures

BACKGROUND K wire fixation with tension band wiring has conventionally been used for the open reduction and internal fixation of the patella. However, it suffers from distinct disadvantages such as implant irritation, need for open reduction, incidence of palpable implants, and need for subsequent implant removal. A smaller incision with percutaneous fixation may be an alternative to this estab...

متن کامل

Current concepts review: Fractures of the patella

Fractures of the patella account for about 1% of all skeletal injuries and can lead to profound impairment due to its crucial function in the extensor mechanism of the knee. Diagnosis is based on the injury mechanism, physical examination and radiological findings. While the clinical diagnosis is often distinct, there are numerous treatment options available. The type of treatment as well as th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016