Cardiac Valve Prostheses

نویسندگان

  • Ulrich Nellessen
  • Ingela Schnittger
چکیده

To determine the value of transesophageal ultrasound in the assessment of cardiac valve prostheses, 14 patients with clinically suspected mitral prosthesis malfunction were studied by transthoracic and transesophageal two-dimensional imaging as well as by color Doppler flow velocity mapping (color Doppler). Patients underwent left ventricular angiography (n = 13), surgery (n =11), or both angiography and surgery (n = 10). Nine patients had only mitral valve replacement, four patients had both mitral and aortic valve replacement, and one patient had mitral, aortic, and tricuspid valve replacement. There were 16 biological and four mechanical prostheses. The degree of mitral regurgitation was graded by both transthoracic and transesophageal color Doppler according to the area of the regurgitant jet visualized and was compared with a three-point classification of mitral regurgitation by left ventricular angiography judged by observers blinded to the echocardiographic results. All transesophageal studies were performed without complication and were well tolerated. The pathological morphology of the mitral prosthesis was additionally or more clearly visualized by transesophageal twodimensional imaging and subsequently proven at surgery in three patients with flail leaflets and one patient with a vegetation compared with images obtained by the transthoracic approach. Valvular regurgitation was graded by the transthoracic approach as absent in four patients, mild in two patients, moderate in five patients, and severe in only three patients. The transesophageal assessment showed absence of mitral regurgitation in two patients, moderate regurgitation in two patients, and severe regurgitation in 10 patients. Left ventricular angiography done in 13 of the 14 patients revealed no regurgitation in two patients, mild regurgitation in one patient, moderate regurgitation in one patient, and severe mitral regurgitation in nine patients. This corresponded to the grading by transesophageal echocardiography in 12 of the 13 patients with the 13th patient graded as mild regurgitation by angiography and moderate regurgitation by transesophageal echocardiography. We conclude that in patients with biological mitral prosthesis malfunction, transesophageal two-dimensional imaging, as well as color Doppler, can provide reliable diagnostic information beyond that available from the transthoracic approach with the degree of mitral regurgitation corresponding to that found on left ventricular angiography. (Circulation 1988;78:848-855)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic function of the Kay-Shiley prosthetic cardiac valve. Observations after mitral or tricuspid valve replacement.

Eighteen patients were catheterized before and nine months (average) after mitral and/or tricuspid valve replacement with the KayShiley prosthesis. In 14 patients with Kay-Shiley mitral prostheses, average cardiac index rose from 2.2 L/min/M"reoperatively to 2.8 postoperation, average left atrial mean pressure fell from 26 to 18 mm Hg, and the average left atrioventricular mean diastolic gradie...

متن کامل

Dynamic three-dimensional reconstruction of the heart by transesophageal echocardiography.

OBJECTIVE To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS Twenty patients were studied consecutively. Th...

متن کامل

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Development and manufacture of prosthetic cardiac valves. Mexican cardiac valvular prostheses

A brief account of the history of the development of cardiac valvular prostheses is given. The use of these devices is analyzed. The authors describe the successive stages of the use of the various types of mechanical prosthetic valves with special reference to the experience in Mexico. They refer to the manufacture of testing and clinical results with the Biomed valves made in Mexico. It is co...

متن کامل

Prosthetic Aortic Heart Valves

In this review, the anatomy and structure of the aortic valve and its prostheses are comprehensively discussed. Cardiac anatomy and function, human heart valves and their prostheses are also extensively discussed. The current status of prosthetic heart valves along with the next generation of these devices is broadly deliberated. Ather promising options such astranscatheter technologies (percut...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005