Plasma meniscus and extraction electrode studies of the ISIS H- ion source.
نویسندگان
چکیده
In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H(-) ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the present geometry requires optimization. This paper details the experimental and simulation studies performed of the plasma meniscus and the possible electrode geometry modifications needed to extract the highest quality beam.
منابع مشابه
Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation.
Linac4 accelerator of Centre Européen de Recherches Nucléaires is under construction and a RF-driven H(-) ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 9...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملInstalling the Vespa H Ion Source Test Stand at Ral
A Penning-type negative hydrogen (H) ion source has been used reliably on the ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK for almost 30 years. However a detailed study of the ion source plasma and extraction has never been undertaken. If these properties were known, the beam emittance and losses due to collimation could be reduced, and ...
متن کاملApplication of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion
A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...
متن کاملApplication of 3D code IBSimu for designing an H−/D− extraction system for the Texas A&M facility upgrade
A three dimensional ion optical code IBSimu is being developed at the University of Jyväskylä. So far the plasma modelling of the code has been restricted to positive ion extraction systems, but now a negative ion plasma extraction model has been added. The plasma model has been successfully validated with simulations of the Spallation Neutron Source (SNS) ion source extraction both in cylindri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 81 2 شماره
صفحات -
تاریخ انتشار 2010