Comparison of Bone Loss around Bone Platform Shift and Non-Bone Platform Shift Implants After 12 Months
نویسندگان
چکیده
OBJECTIVES The aim of the present randomized clinical trial was to evaluate marginal bone loss around two types of implants modified at the neck area: Nobel Active and Nobel Replace Groovy, both manufactured by Nobel Biocare. MATERIALS AND METHODS A total of 25 Nobel Active and 21 Nobel Replace Groovy implants were included in the present study. The implants were placed based on the relevant protocol and patient inclusion and exclusion criteria. The amount of bone loss around implants was compared at 6 and 12-month intervals using digital periapical radiographs. RESULTS The mean bone loss values in the Nobel Active and Nobel Replace Groovy groups were 0.682 mm and 0.645 mm, respectively, with no statistically significant difference based on the results of independent t-test (P=0.802). CONCLUSION Use of both implant types yielded favorable results, with high durability. The two implant types exhibited no superiority over each other in terms of bone loss.
منابع مشابه
مقایسه میزان تحلیل استخوان کرستال اطراف ایمپلنتهای Replace با دو روش Submerge و Non-submerge
Background and Aim: It is well recognized that implant treatment is common worldwide, but the approach to success is not predictable because of bone loss that occurs around the implants. Also there are many factors affecting crestal bone loss around the implants that one of them is the surgical protocol of implant installation. The purpose of this investigation was to evaluate the amount of cre...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملمقایسه شاخصهای سلامتی لثه در افراد دریافت کننده ایمپلنتهای دندانی سیگاری و غیرسیگاری
Background : Although factors such as implant length, location, and diameter as well as bone quality have been associated with excessive failure rates, smoking is suggested as a stronger predisposing factor for higher failure rates. Thus, knowing the relationship between bone loss around the dental implants, maintenance of the implants and smoking could be a principle step towards solving the...
متن کاملRadiographic Evaluation of Marginal Bone Loss Following Immediate and Delayed Implantation
Background and Aim: Intraosseous implants can be placed using three different techniques: immediate, early, and delayed. The aim of this study was to compare the changes in the marginal bone level around implants after immediate and delayed im-plant placement. Materials and Methods: In the present prospective cohort study, 26 implants were placed in 26 patients divided into two groups. In grou...
متن کامل