Static beam tomotherapy as an optimisation method in whole‐breast radiation therapy (WBRT)

نویسندگان

  • Matthew Squires
  • Yunfei Hu
  • Mikel Byrne
  • Ben Archibald-Heeren
  • Sonja Cheers
  • Bruno Bosco
  • Amy Teh
  • Andrew Fong
چکیده

INTRODUCTION TomoTherapy (Accuray, Sunnyvale, CA) has recently introduced a static form of tomotherapy: TomoDirect™ (TD). This study aimed to evaluate TD against a contemporary intensity modulated radiation therapy (IMRT) alternative through comparison of target and organ at risk (OAR) doses in breast cancer cases. A secondary objective was to evaluate planning efficiency by measuring optimisation times. METHODS Treatment plans of 27 whole-breast radiation therapy (WBRT) patients optimised with a tangential hybrid IMRT technique were replanned using TD. Parameters included a dynamic field width of 2.5 cm, a pitch of 0.251 and a modulation factor of 2.000; 50 Gy in 25 fractions was prescribed and planning time recorded. The planning metrics used in analysis were ICRU based, with the mean PTV minimum (D99 ) used as the point of comparison. RESULTS Both modalities met ICRU50 target heterogeneity objectives (TD D99 = 48.0 Gy vs. IMRT = 48.1 Gy, P = 0.26; TD D1 = 53.5 Gy vs. IMRT = 53.0 Gy, P = 0.02; Homogeneity index TD = 0.11 vs. IMRT = 0.10, P = 0.03), with TD plans generating higher median doses (TD D50 = 51.1 Gy vs. IMRT = 50.9 Gy, P = 0.03). No significant difference was found in prescription dose coverage (TD V50 = 85.5% vs. IMRT = 82.0%, P = 0.09). TD plans produced a statistically significant reduction in V5 ipsilateral lung doses (TD V5 = 23.2% vs. IMRT = 27.2%, P = 0.04), while other queried OARs remained comparable (TD ipsilateral lung V20 = 13.2% vs. IMRT = 14.6%, P = 0.30; TD heart V5 = 2.7% vs. IMRT = 2.8%, P = 0.47; TD heart V10 = 1.7% vs. IMRT = 1.8%, P = 0.44). TD reduced planning time considerably (TD = 9.8 m vs. IMRT = 27.6 m, P < 0.01), saving an average planning time of 17.8 min per patient. CONCLUSIONS TD represents a suitable WBRT treatment approach both in terms of plan quality metrics and planning efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TomoDirect: an efficient means to deliver radiation at static angles with tomotherapy.

AIMS AND BACKGROUND The TomoTherapy Hi-Art II system is able to deliver dynamic intensity-modulated radiation therapy within a helical geometry providing robust conformality and modulation, abrupt dose falloff, and reliable accuracy. A new upgrade named TomoDirect was introduced recently, allowing delivery of radiation at discrete angles with a fixed gantry. We present our preliminary clinical ...

متن کامل

Dosimetric Evaluation of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Helical Tomotherapy for Hippocampal-Avoidance Whole Brain Radiotherapy

BACKGROUND Whole brain radiotherapy (WBRT) is a vital tool in radiation oncology and beyond, but it can result in adverse health effects such as neurocognitive decline. Hippocampal Avoidance WBRT (HA-WBRT) is a strategy that aims to mitigate the neuro-cognitive side effects of whole brain radiotherapy treatment by sparing the hippocampi while delivering the prescribed dose to the rest of the br...

متن کامل

A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation.

PURPOSE AND BACKGROUND Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast i...

متن کامل

Intensity-modulated radiotherapy using two static ports of tomotherapy for breast cancer after conservative surgery: dosimetric comparison with other treatment methods and 3-year clinical results

This study investigated the differences in dose-volume parameters for the breast and normal tissues during TomoDirectTM (TD) intensity-modulated radiation therapy (IMRT), TD-3D conformal radiotherapy (3DCRT) and 3DCRT plans, all using two beams, and analyzed treatment outcomes of two-beam TD-IMRT for breast cancer after breast-conserving surgery. Between August 2011 and January 2015, 152 patien...

متن کامل

Use of Helical TomoTherapy for the Focal Hypofractionated Treatment of Limited Brain Metastases in the Initial and Recurrent Setting

BACKGROUND Whole-brain radiation therapy (WBRT), stereotactic radiosurgery (SRS), or both are commonly employed in the treatment of limited brain metastases in the initial or recurrent setting. Hypofractionated partial volume irradiation is also employed, however, published experience using helical TomoTherapy (HT) for this purposes is limited. We reviewed our institutional experience to assess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 64  شماره 

صفحات  -