Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing.

نویسندگان

  • J A Taylor
  • C A Morillo
  • D L Eckberg
  • K A Ellenbogen
چکیده

OBJECTIVES We determined the short-term effects of single-chamber ventricular pacing and dual-chamber atrioventricular (AV) pacing on directly measured sympathetic nerve activity. BACKGROUND Dual-chamber AV cardiac pacing results in greater cardiac output and lower systemic vascular resistance than does single-chamber ventricular pacing. However, it is unclear whether these hemodynamic advantages result in less sympathetic nervous system outflow. METHODS In 13 patients with a dual-chamber pacemaker, we recorded the electrocardiogram, noninvasive arterial pressure (Finapres), respiration and muscle sympathetic nerve activity (microneurography) during 3 min of underlying basal heart rate and 3 min of ventricular and AV pacing at rates of 60 and 100 beats/min. RESULTS Arterial pressure was lowest and muscle sympathetic nerve activity was highest at the underlying basal heart rate. Arterial pressure increased with cardiac pacing and was greater with AV than with ventricular pacing (change in mean blood pressure +/- SE: 10 +/- 3 vs. 2 +/- 2 mm Hg at 60 beats/min; 21 +/- 5 vs. 14 +/- 2 mm Hg at 100 beats/min; p < 0.05). Sympathetic nerve activity decreased with cardiac pacing and the decline was greater with AV than with ventricular pacing (60 beats/min -40 +/- 11% vs. -17 +/- 7%; 100 beats/min -60 +/- 9% vs. -48 +/- 10%; p < 0.05). Although most patients showed a strong inverse relation between arterial pressure and muscle sympathetic nerve activity, three patients with severe left ventricular dysfunction (ejection fraction < or = 30%) showed no relation between arterial pressure and sympathetic activity. CONCLUSIONS Short-term AV pacing results in lower sympathetic nerve activity and higher arterial pressure than does ventricular pacing, indicating that cardiac pacing mode may influence sympathetic outflow simply through arterial baroreflex mechanisms. We speculate that the greater incidence of adverse outcomes in patients treated with single-chamber ventricular rather than dual-chamber pacing may be due in part to increased sympathetic nervous outflow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block.

OBJECTIVE To compare symptoms and exercise tolerance during dual chamber universal (DDD) and ventricular rate response (VVIR) pacing in elderly (> or = 75) patients. DESIGN Randomised, double blind, crossover study. SETTING Regional cardiac department. PATIENTS Twenty elderly patients (mean age 80.5 (1) years) with high grade atrioventricular block and sinus rhythm. Patients with pre-exis...

متن کامل

"Subclinical" pacemaker syndrome: a randomised study of symptom free patients with ventricular demand (VVI) pacemakers upgraded to dual chamber devices.

OBJECTIVE To determine whether symptom free patients with single chamber pacemakers benefit from dual chamber pacing. DESIGN A randomised double blind crossover comparison of ventricular demand (VVI), dual chamber demand (DDI), and dual chamber universal (DDD) modes after upgrading from a VVI device. SETTING Cardiology outpatient department. PATIENTS Sixteen patients aged 41-84 years who ...

متن کامل

Who Needs Physiologic Pacing and Why?

Various pacing technologies have been developed during the past 50 years since the first pacemaker was implanted in 1958. Dual-chamber pacing, rate responsiveness, programmable and rate-responsive atrioventricular (AV) intervals, alternative-site pa0cing, and new multichamber pacing devices are all attempts to mimic normal cardiac physiology as much as feasible. The categories of alternative-si...

متن کامل

Cardiac pacing for severe childhood neurally mediated syncope with reflex anoxic seizures.

OBJECTIVE To determine whether permanent cardiac pacing could prevent syncope and seizures in children with frequent severe neurally mediated syncope, and if so whether dual chamber pacing was superior to single chamber ventricular pacing. METHODS Dual chamber pacemakers were implanted into 12 children (eight male, four female) aged 2-14 years (median 2.8 years) with frequent episodes of refl...

متن کامل

Benefits of dual chamber pacing in sick sinus syndrome.

The effects of DDD (fully automatic) and VVI (ventricular demand) pacing modes on exercise tolerance, symptom diary cards, and Holter monitoring were investigated in a randomised double blind crossover study of 16 patients who had had DDD pacemakers implanted because of frequent syncope. Eight patients presented with sick sinus syndrome and, with one exception, retrograde atrioventricular condu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 1996