A simple method for the construction of electrode arrays.

نویسندگان

  • A J Verloop
  • J Holsheimer
چکیده

A simple method is described for the construction of electrode arrays consisting of insulated metal wires (33 microns diameter) spaced at small, equal distances (0.1 mm). No specialized instrumentation and techniques are needed, as only simple mechanical tools are sufficient. The electrode arrays are used for field potential recording from in vitro brain slice preparations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-electrode arrays technology for the non-invasive recording of neural signals: a review article

The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...

متن کامل

Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)

In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...

متن کامل

Construction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method

In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...

متن کامل

Silica Nanoparticles Modified Carbon Paste Electrode as a Voltammetric Sensor for Determination of Diclofenac

The present study describes the use of a new carbon paste electrode modified by means of Silica nanoparticles prepared by a simple and rapid procedure for the determination of sodium diclofenac (DCF). Moreover, the present study focuses on the characterization of electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) of the prepared Silica NPs-CPE. In this work, The...

متن کامل

Detection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode

The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 1984