Drug-eluting stents appear superior to bare metal stents for vein-graft PCI in vessels up to a stent diameter of 4 mm

نویسندگان

  • Oliver P. Guttmann
  • Daniel A. Jones
  • Kassem A. Safwan
  • Sean Gallagher
  • Krishnaraj S. Rathod
  • Steve Hamshere
  • Elliot J. Smith
  • Ajay K. Jain
  • Anthony Mathur
  • Andrew Wragg
  • Charles J. Knight
  • Roshan Weerackody
چکیده

BACKGROUND Research trials have shown improved short-term outcome with drug-eluting stents (DES) over bare metal stents (BMS) in saphenous vein graft (SVG) percutaneous coronary intervention (PCI), primarily by reducing target vessel revascularization (TVR) for in-stent restenosis. We compared the outcomes in patients undergoing SVG stent implantation treated with DES or BMS. In exploratory analyses we investigated the influence of stent generation and diameter. METHODS Data were obtained from a prospective database of 657 patients who underwent PCI for SVG lesions between 2003 and 2011. A total of 344 patients had PCI with BMS and 313 with DES. Propensity scores were developed based on 15 observed baseline covariates in a logistic regression model with stent type as the dependent variable. The nearest-neighbour-matching algorithm with Greedy 5-1 Digit Matching was used to produce two patient cohorts of 313 patients each. We assessed major adverse cardiac events (MACE) out to a median of 3.3 years (interquartile range: 2.1-4.1). MACE was defined as all-cause mortality, myocardial infarction (MI), TVR and stroke. RESULTS There was a significant difference in MACE between the two groups in favour of DES (17.9% DES vs. 31.2% BMS group; p = 0.0017) over the 5-year follow-up period. MACE was driven by increased TVR in the BMS group. There was no difference in death, MI or stroke. Adjusted Cox analysis confirmed a decreased risk of MACE for DES compared with BMS 0.75 (95% confidence interval (CI) 0.52-0.94), with no difference in the hazard of all-cause mortality (hazard ratio: 1.08; 95% CI: 0.77-1.68). However, when looking at stent diameters greater than 4 mm, no difference was seen in MACE rates between BMS and DES. CONCLUSIONS Overall in our cohort of patients who had PCI for SVG disease, DES use resulted in lower MACE rates compared with BMS over a 5-year follow-up period; however, for stent diameters over 4 mm no difference in MACE rates was seen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late outcomes of drug eluting and bare metal stents in saphenous vein graft percutaneous coronary intervention.

AIMS PCI with drug eluting stents (DES) has been shown to reduce restenosis and major adverse cardiac event (MACE) rates compared to bare metal stents (BMS) in native coronary vessels, although outcomes in saphenous vein graft (SVG) lesions are less clear. We retrospectively studied 388 consecutive patients admitted to our centre for SVG PCI to assess mortality and MACE outcomes (defined as com...

متن کامل

بررسی نتیجه کلینیکی بلند مدت آنژیوپلاستی با استنت فلزی در بیماران مبتلا به بیماری عروق کرونر در بیمارستان فاطمه زهرا (س) ساری از سال 1383 تا سال 1385

Background and Purpose:Coronary artery Stenting is known to improve the outcome for ischemic heart disease. Many clinical studies have been performed to determine the long-term outcome of coronary Stenting and most of them were based on first-generation bare-metal Stents. The aim of this study is to evaluate long-term (24 6.4 month) results of second-generation bare metal stent. Materials an...

متن کامل

Drug-Eluting Stents Versus Bare Metal Stents in Saphenous Vein Graft Intervention.

Percutaneous coronary intervention (PCI) of saphenous vein graft (SVG) is associated with higher adverse event rates, lower procedural success, and inferior longterm patency rates compared with native vessel PCI. The ability to comply with dual antiplatelet therapy, and whether the patient will need an interruption in dual antiplatelet therapy, should be considered when deciding whether to impl...

متن کامل

Comparison of stent graft, sirolimus stent, and bare metal stent implanted in patients with acute coronary syndrome: clinical and angiographic follow-up.

AIM To compare polytetrafluoroethylene stent graft (PTFE) with sirolimus and bare metal stents in reducing in-stent restenosis in native coronary vessels in patients with acute coronary syndrome. METHODS The study included patients who underwent stent implantation in acute coronary syndrome from January 2003 to May 2004. The patients (n=119) were randomized either to stent graft group (n=40),...

متن کامل

Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions.

OBJECTIVES To define long-term efficacy of different stent types in saphenous vein graft (SVG) interventions. METHODS In BASKET (Basel Stent Cost Effectiveness Trial), major adverse cardiac events (MACE), i.e. cardiac death, myocardial infarction and symptom-driven target vessel revascularization (TVR) were assessed after 18 months comparing drug-eluting stents (DES) versus bare metal stents ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016