Strength measurements of the intrinsic hand muscles: a review of the development and evaluation of the Rotterdam intrinsic hand myometer.
نویسندگان
چکیده
Numerous neurological diseases are accompanied by atrophy of the intrinsic muscles of the hand. Muscle strength testing of these muscles is frequently used for clinical decision making. Traditionally, these strength measurements have focused on manual muscle testing (MMT) or on grip and pinch strength dynamometry. We have developed a hand-held dynamometer, the Rotterdam Intrinsic Hand Myometer (RIHM), to measure this intrinsic muscle strength. The RIHM was designed such that it can measure a wide range of muscle groups, such as the abduction and adduction strength of the little finger and index finger, the opposition, palmar abduction (anteposition) and opposition strength of the thumb, and intrinsic muscles of the fingers combined in the intrinsic plus position. We found that the reliability of RIHM measurements in nerve injury patients was comparable to grip and pinch strength measurements and is appropriate to study the functional recovery of the intrinsic muscles of the hand in isolation. We have applied the RIHM in a recent study on the long-term outcome of muscle strength in patients with ulnar and median nerve injuries and found that while recovery of grip and pinch strength was relatively good, recovery of the ulnar nerve innervated muscles measured with the RIHM was poor. This poor recovery could not be detected with manual muscle strength testing or with grip and pinch dynamometry. We conclude that the RIHM provides an accurate clinical assessment of the muscle strength of the intrinsic hand muscles that adds valuable information to MMT and grip and pinch dynamometry.
منابع مشابه
Dynamometry of intrinsic hand muscles in patients with Charcot-Marie-Tooth disease.
BACKGROUND Several problems are associated with manual muscle testing and dynamometry in the hands of patients with Charcot-Marie-Tooth (CMT) disease. OBJECTIVE To evaluate the efficacy of the Rotterdam Intrinsic Hand Myometer (RIHM) to directly measure intrinsic hand muscle strength in CMT disease. METHODS We measured hand muscle strength and hand function in 41 patients with CMT disease. ...
متن کاملMeasuring the strength of the intrinsic muscles of the hand in patients with ulnar and median nerve injuries: reliability of the Rotterdam Intrinsic Hand Myometer (RIHM).
PURPOSE To determine the reliability and measurement error of measurements of intrinsic muscle strength of a new hand-held dynamometer (the Rotterdam Intrinsic Hand Myometer [RIHM]). METHODS With the RIHM we obtained repeated measurements of the intrinsic muscle strength of the hand in 27 patients with peripheral nerve injury of the ulnar and/or median nerve in different stages of rehabilitat...
متن کاملLong-term outcome of muscle strength in ulnar and median nerve injury: comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer.
OBJECTIVE To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). METHODS Thirty-four patients more than 2 years after ulnar and/or median nerve injury. Muscle strength was evaluated using ma...
متن کاملThe hypothesis of overwork weakness in Charcot-Marie-Tooth: a critical evaluation.
OBJECTIVE It has been reported that the non-dominant hand of patients with Charcot-Marie-Tooth disease is stronger than the dominant hand as a result of overwork weakness. The objective of this study was to determine if this hypothesis could be verified in our population. DESIGN Survey. SUBJECTS Twenty-eight patients with Charcot-Marie-Tooth disease type I or II from a rehabilitation depart...
متن کاملStrength of the intrinsic muscles of the hand measured with a hand-held dynamometer: reliability in patients with ulnar and median nerve paralysis.
The aim of this study was to assess the reliability of a technique to measure the strength of the intrinsic hand muscles. Intraclass Correlation Coefficients showed an excellent level of reliability for the comparison of muscle strength between groups of patients. However, for the results of individual patients, the calculated Standard Error of Measurements (10-16%) and the Smallest Detectable ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of hand therapy : official journal of the American Society of Hand Therapists
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2006