Switching monitoring of emulsified cyclosporine from trough level to 2-hour level in stable liver transplant patients.

نویسندگان

  • Pieter Langers
  • Serge C L M Cremers
  • Jan den Hartigh
  • Roeland A Veenendaal
  • W Rogier ten Hove
  • Jan Ringers
  • Cornelis B H W Lamers
  • Bart van Hoek
چکیده

After orthotopic liver transplantation (OLT) many patients use emulsified cyclosporine. Recent data showed that blood levels 2 hours after dosing (C-2) better reflect systemic exposure to the drug (area under the blood concentration time curve) than trough levels (C-0) do. We investigated difference in dosage, creatinine clearance (CrCl), blood pressure (BP), freedom from rejection, and relation of C-2, C-0, and AUC while switching 31 stable patients more than 6 months after OLT from C-0 to C-2 monitoring. With C-0 between 90 and 150 ng/mL we collected 24-hour urine, while blood samples were taken at t = 0, 1, 2, 3, 4, 6, and 8 hours after dosing to measure cyclosporine, creatinine, liver tests, and blood pressure and calculated AUC and CrCl. Target AUC was calculated based on C-0. Then the dose was adjusted to two subsequent C-2 values of 600 ng/mL +/- 15%, the above was repeated, and the differences were assessed. Cyclosporine dose was reduced in 21/31 patients (68%) and remained unchanged in 10/31 patients (32%) after conversion. Mean lowering was 69 mg daily (26.9 %, P < 0.0001). After dose reduction the mean increase of CrCl was 7.93 ml/min (11.6%, P = 0.016). Only systolic and mean morning BP decreased slightly but significantly. C-2 correlated better with AUC0-12 (r2 = 0.75) than C-0 (r2 = 0.64). However, 13/21 patients had a second AUC below target AUC and 2 of these 13 patients developed rejection after conversion to C-2 levels. In conclusion, while C-0 monitoring frequently results in overdosing and more renal dysfunction, C-2 monitoring may lead to episodes of underdosing and rejection. Therefore better ways of monitoring cyclosporine dosing need to be devised.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Efficacy of Amlodipine and Diltiazem in Cyclosporine Dose Adjustment with Respect to Trough and 2-hour Concentrations in Kidney Transplant Patients

Background & Aims: Hypertension, hyperuricaemia and nephrotoxicity are some common side-effects of Cyclosporine A (CsA) treatment in renal transplant recipients. Previous studies suggest that Calcium Channel Blockers (CCB) can increase serum level of CsA and may improve graft function in patients receiving CsA. The aim of this study was to evaluate the effects of Diltiazem and Amlodipine on cyc...

متن کامل

The Relationship between the Plasma Level of Cyclosporine-A and Drug Dose in Patients of Kermanshah Kidney Transplantation Center

Background: Nowadays the main problem in transplantation is the complexity of host immune system protection against the immunological and destructive reactions of the transplanted organ. High serum level of the immunosuppressive drug may cause toxicity and low serum level leads to the rejection of the transplanted organ. Cyclosporine has been known as the most effective immunosuppressive drug. ...

متن کامل

پایش درمانی سیکلوسپورین-آ در کودکان ایرانی با کلیه پیوندی

  Background & Aim: Cyclosporine-A (CsA) is an immunosuppressant with a narrow therapeutic window. Inter-and-intrapatient variability in cyclosporine pharmacokinetics necessitates frequent blood level monitoring in transplant patients and total blood cyclosporine concentration used to allow dosage adjustment in transplant patients. The purpose of the present study was, first of all, to develop ...

متن کامل

Laboratory Monitoring of Cyclosporine Pre-dose Concentration (C0) After Kidney Transplantation in Isfahan

Background: Cyclosporine is the main immunosuppressive agent used in organ transplantation which leads to considerable improvement in graft survival.  The large inter- and intra- patient variability in cyclosporine pharmacokinetics coupled with the agent’s narrow therapeutic index and adverse effects necessitate therapeutic monitoring of cyclosporine blood levels. Objective: The aim of this stu...

متن کامل

A Review on Therapeutic Drug Monitoring of Immunosuppressant Drugs

Immunosuppressants require therapeutic drug monitoring because of their narrow therapeutic index and significant inter-individual variability in blood concentrations. This variability can be because of factors like drug-nutrient interactions, drug-disease interactions, renal-insufficiency, inflammation and infection, gender, age, polymorphism and liver mass. Drug monitoring is widely practiced ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 2004