Detection of thrombus size and protein content by ex vivo magnetization transfer and diffusion weighted MRI
نویسندگان
چکیده
BACKGROUND To utilize a rabbit model of plaque disruption to assess the accuracy of different magnetic resonance sequences [T1-weighted (T1W), T2-weighted (T2W), magnetization transfer (MT) and diffusion weighting (DW)] at 11.7 T for the ex vivo detection of size and composition of thrombus associated with disrupted plaques. METHODS Atherosclerosis was induced in the aorta of male New Zealand White rabbits (n = 17) by endothelial denudation and high-cholesterol diet. Subsequently, plaque disruption was induced by pharmacological triggering. Segments of infra-renal aorta were excised fixed in formalin and examined by ex vivo magnetic resonance imaging (MRI) at 11.7 T and histology. RESULTS MRI at 11.7 T showed that: (i) magnetization transfer contrast (MTC) and diffusion weighted images (DWI) detected thrombus with higher sensitivity compared to T1W and T2W images [sensitivity: MTC = 88.2%, DWI = 76.5%, T1W = 66.6% and T2W = 43.7%, P < 0.001]. Similarly, the contrast-to-noise (CNR) between the thrombus and the underlying plaque was superior on the MTC and DWI images [CNR: MTC = 8.5 ± 1.1, DWI = 6.0 ± 0.8, T1W = 1.8 ± 0.5, T2W = 3.0 ± 1.0, P < 0.001]; (ii) MTC and DWI provided a more accurate detection of thrombus area with histology as the gold-standard [underestimation of 6% (MTC) and 17.6% (DWI) compared to an overestimation of thrombus area of 53.7% and 46.4% on T1W and T2W images, respectively]; (iii) the percent magnetization transfer rate (MTR) correlated with the fibrin (r = 0.73, P = 0.003) and collagen (r = 0.9, P = 0.004) content of the thrombus. CONCLUSIONS The conspicuity of the thrombus was increased on MTC and DW compared to T1W and T2W images. Changes in the %MTR and apparent diffusion coefficient can be used to identify the organization stage of the thrombus.
منابع مشابه
In vivo magnetization transfer and diffusion-weighted magnetic resonance imaging detects thrombus composition in a mouse model of deep vein thrombosis.
BACKGROUND Deep vein thrombosis remains a major health problem necessitating accurate diagnosis. Thrombolysis is associated with significant morbidity and is effective only for the treatment of unorganized thrombus. We tested the feasibility of in vivo magnetization transfer (MT) and diffusion-weighted magnetic resonance imaging to detect thrombus organization in a murine model of deep vein thr...
متن کاملمقایسه Diffusion-MRI با MRI متداول در کشف ضایعات داخل مغزی مولتیپل اسکلروزیس
Background: Multiple sclerosis (MS) is a chronic disease that begins most commonly in young adults and is characterized pathologically by multiple areas of central nervous system (CNS) white matter inflammation, demyelination, and glial scarring. The most valuable aid for diagnosis is magnetic resonance imaging (MRI). New type of MRI has been developed on the basis of molecular diffusion which ...
متن کاملHigh-resolution 3d Diffusion Mri: Detection of Lipid-rich Necrotic Core in Plaques without Contrast Media
Purpose: Large lipid-rich necrotic core (LRNC) is a well-known feature of rupture-prone atherosclerotic plaque , which is the major cause of both stroke and transient ischemic attack. Plaque lipid content has also been used clinically to monitor disease progression and the results of therapeutic interventions. Although contrast-enhanced (CE) MRI was shown possible for LRNC detection, patients w...
متن کاملThe Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI)
Introduction: Multiple sclerosis (MS) is a demyelinating disease of the central nervous system (CNS), affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI) is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathologic...
متن کاملMagnetization transfer imaging shows tissue abnormalities in the reversible penumbra.
BACKGROUND AND PURPOSE In the concept of ischemic penumbra, the volume of salvaged penumbra is considered as the volume of FLAIR normalization on follow-up MRI compared with early diffusion and perfusion abnormalities. Using magnetization transfer imaging, very sensitive to macromolecular disruption, we investigated whether FLAIR normalization was a good marker for tissue full recovery. METHO...
متن کامل