Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS
نویسنده
چکیده
v Chapter 1. General Introduction 1 Historical Perspectives 1 Fundamental Aspects of ICP-MS 2 ICP-MS Instrumentation 3 Blank Purity in ICP-MS 4 Previous EMLC Experiments 6 Matrix Effects in ICP-MS 7 Flow Injection in ICP-MS 9 Shielded Torch in ICP-MS 10 Dissertation Objectives and Organization 11 Figures 12 References 27 Chapter 2. Electrochemically-Modulated Liquid Chromatography for Cleaning the Blank in Inductively Coupled Plasma – Mass Spectrometry 31 Abstract 3
منابع مشابه
Nafion-coated bismuth film and nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry.
Nafion-coated bismuth film electrodes (NCBFEs) and Nafion-coated mercury film electrodes (NCMFEs) were used to electrochemically preconcentrate metal analytes for subsequent analysis by inductively coupled plasma-mass spectrometry (ICP-MS). Either type of electrodes is part of a thin-layer electrochemical flow cell that is positioned upstream of a microconcentric nebulizer for the ICP-MS. Perfo...
متن کاملAn overview of analytical applications of time of flight-mass spectrometric (TOF-MS) analyzers and an inductively coupled plasma-TOF-MS technique.
A brief overview of the applications of time-of-flight mass spectrometry (TOF-MS) for analytical purposes is presented. The performance of TOF-MS combined with an inductively coupled plasma (ICP) ion source is discussed in detail. The advantages of TOF-MS detectors over the quadrupole mass filters for multi-elemental analysis of fast transient signals are discussed. The applications of ICP-TOF-...
متن کاملAnalysis of mono-phosphate nucleotides as a potential method for quantification of DNA using high performance liquid chromatography-inductively coupled plasma-mass spectrometry.
The determination of total deoxyribonucleic acid (DNA) concentration is of great importance in many biological and bio-medical analyses. The quantification of DNA is traditionally performed by UV spectroscopy; however the results can be affected greatly by the sample matrix. The proposed method quantifies phosphorus in digested calf thymus DNA and human DNA by high performance liquid chromatogr...
متن کاملA Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application
An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...
متن کاملHigh temperature liquid chromatography hyphenated with ESI-MS and ICP-MS detection for the structural characterization and quantification of halogen containing drug metabolites.
In this paper we describe the hyphenation of high temperature liquid chromatography with ICP-MS and ESI-MS for the characterization of halogen containing drug metabolites. The use of temperature gradients up to 200°C enabled the separation of metabolites with low organic modifier content. This specific property allowed the use of detection methods that suffer from (significant) changes in analy...
متن کامل