Axillary temperature measurement: a less stressful alternative for hospitalised cats?
نویسندگان
چکیده
Rectal temperature measurement (RTM) can promote stress and defensive behaviour in hospitalised cats. The aim of this study was to assess if axillary temperature measurement (ATM) could be a reliable and less stressful alternative for these animals. In this prospective study, paired rectal and axillary temperatures were measured in 42 cats, either by a veterinarian or a student. To assess the impact of these procedures on the cat's stress state, their heart rate was checked and a cat stress score (CSS) was defined and graded from 1 (relaxed) to 5 (terrified). A moderate correlation was found between RTM and ATM (r=0.52; P<0.0001). RTM was on average 0.9 °C (1.6 °F) higher than ATM (P<0.0001), although a wide variation was found in the difference between these two measurements (-2.1 °C to 3.6 °C (-3.8 °F to 6.5 °F)). ATM failed to identify hypothermia in 25 per cent of the cases and hyperthermia in 19 per cent of the cases but may be considered less stressful than RTM. Indeed, RTM induced a mildly greater increase in heart rate (+6 bpm; P=0.01) and in CSS (+0.2; P=0.001) than ATM. The results were not affected by operator type. In conclusion, RTM should remain the standard method to obtain accurate temperatures in cats.
منابع مشابه
مقایسه دمای اندازه گیری شده بدن به وسیله ترمومتر جیوه ای و دیجیتالی
Background and Aim: Mercury is a dangerous substance for human health and mercury thermometers are major pollutant for environment. Using less dangerous and less expensive devices like digital thermometer can be an alternative for mercury thermometers. The aim of this study was to compare the body temperature measurement by mercury and digital thermometer. Material and Method : In this desc...
متن کاملComparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult
Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...
متن کاملA Comparative Study on Temperature Accuracy between Tympanic, Rectal, and Axillary Sites
A new method recently used for measuring the temperature is using tympanic thermometer. The aim of this study was to compare the accuracy of this method with rectal and axillary measurement in children less than 6 years old. A total of 220 pair ears, axillaries, and rectal sites were used to determine the body temperature in patients aged between 3 months to 6 years who referred to Emergency De...
متن کاملAccuracy of temporal artery thermometry in neonatal intensive care infants.
PURPOSE To determine the accuracy of temporal artery and axillary temperatures and the discomfort level of stable neonates during temperature measurement. SUBJECTS Convenience sample of neonates between the ages of 32 and 40 weeks' gestation cared for in an isolette or crib. DESIGN A method-comparison design was used to compare different methods for noninvasive temperature monitoring (infra...
متن کاملبررسی مقایسهای درجه حرارت داخل مثانهای و درجه حرارت زیر بغل، مقعدی و دهانی در بیماران پیوند کلیه
Background and Aim: Patients who undergo kidney transplantation take immunosuppressive drugs that make them susceptible to different infections. Since fever is one of prominent symptoms of infection, continuous measurement of temperature is very important. The goal of this research was to find if there is any significant difference between intravesical, oral, rectal and axillary temperatures. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Veterinary record
دوره 178 8 شماره
صفحات -
تاریخ انتشار 2016