Improved capillary electrophoresis method for the determination of carbohydrate-deficient transferrin in patient sera.
نویسندگان
چکیده
Capillary zone electrophoresis (CZE) with a dynamic double coating formed by charged polymeric reagents represents an effective tool for the separation of iron-saturated transferrin (Tf) isoforms and thus the determination of carbohydrate-deficient transferrin (CDT, sum of asialo-, monosialo- and disialo-Tf in relation to total Tf) in human serum. Using the CEofix-CDT reagents, a 50 microm inner diameter (ID) capillary of 60 cm total length and the P/ACE MDQ under optimized instrumental conditions (20 kV and 30 degrees C) is demonstrated to provide outstanding assay precision for the determination of CDT in human serum. For CDT levels of 1.0% and 4.5%, precision relative standard deviation (RSD) values (n = 8) were determined to be < 3.0% and < 1.5%, respectively. During the first year of operation under routine conditions, more than 600 patient samples were analyzed in a total of 62 sets of runs. Except for selected samples of patients with severe liver diseases, interference-free Tf patterns were detected. Asialo-Tf was not detected in control sera and in patient sera with a CDT level < 1.70%, but became detectable in 89.6% of sera with > 2.3% disialo-Tf. Monosialo-Tf was only detected in two sera containing > 13.3% CDT. The optimized CZE assay was applied to confirm positive CDT results produced by an immunoassay during long-term monitoring of a patient which led to the determination of the elimination kinetics of asialo-Tf, disialo-Tf, and CDT after an episode of high alcohol consumption (estimated apparent half lifes of 4.86, 7.24, and 6.74 days, respectively). The optimized CZE assay with an upper reference limit for CDT of 1.70% represents an attractive alternative to high-performance liquid chromatography (HPLC). It features simpler sample preparation, faster analysis time, and higher isoform resolution compared to the most recent HPLC approach and can thus be regarded as a new candidate of a reference method for CDT.
منابع مشابه
Genetic variation in the MTHFR gene influences thiopurine methyltransferase activity.
carbohydrate-deficient glycoprotein syndrome. Electrophoresis 1997;18: 1819–26. 12. Tagliaro F, Crivellente F, Manetto G, Puppi I, Deyl Z, Marigo M. Optimised determination of carbohydrate deficient transferrin isoforms (CDT) in serum by capillary zone electrophoresis. Electrophoresis 1998;19:3033–9. 13. Crivellente F, Fracasso G, Valentini R, Manetto G, Riviera AP, Tagliaro F. Improved method ...
متن کاملDetermination of carbohydrate-deficient transferrin in human serum by capillary zone electrophoresis: evaluation of assay performance and quality assurance over a 10-year period in the routine arena.
The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at ...
متن کاملDetermination of carbohydrate-deficient transferrin using capillary zone electrophoresis.
BACKGROUND Current methods for carbohydrate-deficient transferrin (CDT) often suffer from low precision, complexity, or risk of false positives attributable to genetic variants. In this study, a new capillary zone electrophoresis (CZE) method for CDT was developed. METHODS CZE was performed on a P/ACE 5000 using fused-silica capillaries [50 microm (i.d.) x 47 cm] and the CEOFIX CDT buffer sys...
متن کاملErythrocyte riboflavin for the detection of riboflavin deficiency in pregnant Nepali women.
chronic alcohol abuse in drivers. Forensic Sci Int;in press. 6. Berkowicz A, Wallerstedt S, Wall K, Denison H. Carbohydrate-deficient transferrin in vitreous humour: a marker of possible withdrawal-related death in alcoholics. Alcohol 2001;36:231–4. 7. Helander A, Eriksson G, Stibler H, Jeppsson J-O. Interference of transferrin isoform types with carbohydrate-deficient transferrin quantificatio...
متن کاملCarbohydrate-deficient transferrin measured by capillary zone electrophoresis and by turbidimetric immunoassay for identification of young heavy drinkers.
Carbohydrate-Deficient Transferrin Measured by Capillary Zone Electrophoresis and by Turbidimetric Immunoassay for Identification of Young Heavy Drinkers, Jean-Bernard Daeppen, Frederic Anex, Bernard Favrat, Alvine Bissery, Joelle Leutwyler, Roland Gammeter, Patrice Mangin, and Marc Augsburger ( Alcohol Treatment Center, CHUV, Lausanne, Switzerland; 2 Institute of Forensic Medicine, CHUV, Lausa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electrophoresis
دوره 25 14 شماره
صفحات -
تاریخ انتشار 2004