Response of GafChromic MD-55 film to synchrotron radiation

نویسندگان

  • Nobuteru NARIYAMA
  • Yoshihito NAMITO
  • Syuichi BAN
چکیده

Introduction Recently, owing to the increase of synchrotron radiation facilities such as SPring-8, dose measurements of high-intense low-energy photons are increasingly needed for radiation protection and medical researches. For the dose measurement, tissue equivalence of dosimeter material becomes important. A radiochromic film that has sensitivity in the dose region of several Gy to 100 Gy has been used in medical applications [1]. The film is thin and mainly composed of polyester. The purpose of this study is to measure responses of the double-layer GafChromic film for synchrotron radiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High sensitivity radiochromic film dose comparisons.

This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the...

متن کامل

XR type-R radiochromic film x-ray energy response.

Gafchromic XR type-R radiochromic film is a relatively new product designed for use at clinical diagnostic x-ray energies both qualitatively and quantitatively. This short note investigates the energy response characteristics of this high-sensitivity radiochromic film for both diagnostic and therapeutic x-ray energies. Results are also compared to conventional silver halide x-ray film for energ...

متن کامل

Absorption spectra variations of EBT radiochromic film from radiation exposure.

Gafchromic EBT radiochromic film is one of the newest radiation-induced auto-developing x-ray analysis films available for therapeutic radiation dosimetry in radiotherapy applications. The spectral absorption properties in the visible wavelengths have been investigated and results show two main peaks in absorption located at 636 nm and 585 nm. These absorption peaks are different to many other ...

متن کامل

Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.

A new radiochromic film, GafChromic EBT, was investigated for use in a real-time radiation dosimetry system. It was found to be approximately eight times more sensitive to ionizing radiation dose, exhibited less postexposure development and achieved stable readout faster than one of its predecessors, GafChromic MD-55. A clear distinction in change in optical density between exposure and postexp...

متن کامل

Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter.

The response of radiochromic film, GafChromic EBT, was investigated for dependence on x-ray beam energy using a previously reported real-time optical readout approach. X-ray beams of energy from 75 kVp to 18 MV were employed. The dose-induced change in optical density for the EBT film was compared to values obtained for GafChromic HS and MD-55 films, exposed under the same conditions. All respo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002