Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients
نویسندگان
چکیده
PURPOSE Physiologic monitors are plagued with alarms that create a cacophony of sounds and visual alerts causing "alarm fatigue" which creates an unsafe patient environment because a life-threatening event may be missed in this milieu of sensory overload. Using a state-of-the-art technology acquisition infrastructure, all monitor data including 7 ECG leads, all pressure, SpO(2), and respiration waveforms as well as user settings and alarms were stored on 461 adults treated in intensive care units. Using a well-defined alarm annotation protocol, nurse scientists with 95% inter-rater reliability annotated 12,671 arrhythmia alarms. RESULTS A total of 2,558,760 unique alarms occurred in the 31-day study period: arrhythmia, 1,154,201; parameter, 612,927; technical, 791,632. There were 381,560 audible alarms for an audible alarm burden of 187/bed/day. 88.8% of the 12,671 annotated arrhythmia alarms were false positives. Conditions causing excessive alarms included inappropriate alarm settings, persistent atrial fibrillation, and non-actionable events such as PVC's and brief spikes in ST segments. Low amplitude QRS complexes in some, but not all available ECG leads caused undercounting and false arrhythmia alarms. Wide QRS complexes due to bundle branch block or ventricular pacemaker rhythm caused false alarms. 93% of the 168 true ventricular tachycardia alarms were not sustained long enough to warrant treatment. DISCUSSION The excessive number of physiologic monitor alarms is a complex interplay of inappropriate user settings, patient conditions, and algorithm deficiencies. Device solutions should focus on use of all available ECG leads to identify non-artifact leads and leads with adequate QRS amplitude. Devices should provide prompts to aide in more appropriate tailoring of alarm settings to individual patients. Atrial fibrillation alarms should be limited to new onset and termination of the arrhythmia and delays for ST-segment and other parameter alarms should be configurable. Because computer devices are more reliable than humans, an opportunity exists to improve physiologic monitoring and reduce alarm fatigue.
منابع مشابه
Assessing the Performance of Nurses in the Proper Adjustment of Monitoring Instruments in the Neonatal Intensive Care Unit
Background: Monitoring serves to maintain physiologic variables within normal limits and when a parameter crosses a set threshold, an alarm is triggered. Therefore, this study aimed to determine whether alarm limits are properly adjusted in the neonatal intensive care unit (NICU) by nursing staff or not.Methods: The data concerning alarm limits corresponding to the three shifts of nursing...
متن کاملNurse Competence on Physiologic Monitors Use: Toward Eliminating Alarm Fatigue in Intensive Care Units
BACKGROUND Studies on nurse competence on alarm management are a few and tend to be focused on limited skills. In response to Phase II of implementing the National Patient Safety Goal on clinical alarm systems safety, this study assessed nurses' perceived competence on physiologic monitors use in intensive care units (ICUs) and developed and validated a tool for this purpose. METHODS This des...
متن کاملAssociation between exposure to nonactionable physiologic monitor alarms and response time in a children's hospital.
BACKGROUND Alarm fatigue is reported to be a major threat to patient safety, yet little empirical data support its existence in the hospital. OBJECTIVE To determine if nurses exposed to high rates of nonactionable physiologic monitor alarms respond more slowly to subsequent alarms that could represent life-threatening conditions. DESIGN Observational study using video. SETTING Freestandin...
متن کاملComparison of the Effects of Intralipid 10% and 20% on Peripheral Catheter Ablation in a Pediatric Intensive Care Unit
Background: Energy deficit is a common and serious problem in pediatric intensive care units. Parenteral nutrition, either alone or in combination with enteral nutrition, can improve nutrient delivery in critically ill patients by preventing or correcting the energy deficit and improving the outcomes. Intralipid 10% and 20% are lipid emulsions, widely used in parenteral nutrition. Despite sever...
متن کاملEvaluation of Nutritional Status in a Teaching Hospital Neonatal Intensive Care Unit
Background:Extrauterine growth restriction remains a common and serious problem in newborns especially who are small, immature, and critically ill. Very low birth weight infants (VLBW) had 97% and 40% growth failure at 36 weeks and 18-22 months post-conceptual age respectively. The postnatal development of premature infants is critically dependent on an adequate nutritional intake that mimics a...
متن کامل