Calibration Markers for Digital Templating in Total Hip Arthroplasty

نویسندگان

  • Christoph Kolja Boese
  • Philipp Lechler
  • Leonard Rose
  • Jens Dargel
  • Johannes Oppermann
  • Peer Eysel
  • Hansjörg Geiges
  • Jan Bredow
  • Gwendolen Reilly
چکیده

Digital templating with external calibration markers is the standard method for planning total hip arthroplasty. We determined the geometrical basis of the magnification effect, compared magnification with external and internal calibration markers, and examined the influence on magnification of the position of the calibration markers, patient weight, and body mass index (BMI). A formula was derived to calculate magnification with internal and external calibration markers, informed by 100 digital radiographs of the pelvis. Intraclass correlations between the measured and calculated values and the strength of relationships between magnification, position and distance of calibration markers and height, weight, and BMI were sought. There was a weak correlation between magnification of internal and external calibration markers (r = 0.297-0.361; p < 0.01). Intraclass correlations were 0.882-1.000 (p = 0.000) for all parameters. There were also weak correlations between magnification of internal and external calibration markers and weight and BMI (r = 0.420, p = 0.000; r = 0.428, p = 0.000, respectively). The correlation between external and internal calibration markers was poor, indicating the need for more accurate calibration methods. While weight and BMI weakly correlated with the magnification of markers, future studies should examine this phenomenon in more detail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography–based templating in primary total hip arthroplasty

Background Preoperative total hip arthroplasty templating can be performed with radiographs using acetate prints, digital viewing software, or with computed tomography (CT) images. Our hypothesis is that 3D templating is more precise and accurate with cup size prediction as compared to 2D templating with acetate prints and digital templating software. Methods Data collected from 45 patients u...

متن کامل

Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty.

BACKGROUND The purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty. METHODS We included 18 consecutive patients with primary osteoarthritis undergoing uncemented total hip arthroplasty in our study. At separate sittings, we independently conducted preoperative templating. They per...

متن کامل

Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty.

The use of digital radiography and templating software continues to become more prevalent in orthopedics as the number of total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures increases every year. The purpose of this study was to evaluate the effect of training level on the accuracy of digital templating for primary THA and TKA. Digital radiographs of 97 patients undergoing...

متن کامل

Review of quality of x-rays for templating for total hip arthroplasty.

Digital templating of x-rays for total hip arthroplasty is used routinely for pre-operative planning. This is to assure that appropriately sized implants are selected to replicate patient's hip biomechanics. Multiple studies have shown that templating does not always correspond to the final implants used. The aim of this study was to assess the suitability of the x-rays taken pre-operatively fo...

متن کامل

A comparison of four systems for calibration when templating for total hip replacement with digital radiography.

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015