Transcutaneous versus blood carbon dioxide monitoring during acute noninvasive ventilation in the emergency department - a retrospective analysis.

نویسندگان

  • Christian Michael Horvath
  • Martin Hugo Brutsche
  • Florent Baty
  • Jochen Julius Rüdiger
چکیده

QUESTIONS UNDER STUDY Transcutaneous measurement of carbon dioxide (PtCO2) has been suggested as an alternative to invasively obtained PaCO2 for the monitoring of patients with hypercapnic respiratory failure during noninvasive ventilation (NIV). Current data on monitoring in hypoxaemic respiratory failure are scarce and show conflicting results in hypercapnic patients in the emergency department. METHODS AND SETTING We performed a retrospective comparison of real-time PtCO2 (SenTec Digital Monitor) and arterial/venous carbon dioxide tension (PaCO2/PvCO2) measurements in patients with severe hypoxaemic and/or hypercapnic respiratory failure during NIV. Agreement between PtCO2 and PaCO2/PvCO2 was the primary endpoint. Bland-Altman analysis and linear regression were used. RESULTS 102 patients had at least one matched measurement of PtCO2 and PaCO2/PvCO2. For patients with arterial blood gas analysis, the mean difference was 0.46 kPa at baseline (95% confidence interval [CI] 0.23 to 0.60, limits of agreement 95% CI -0.54 to 1.45) and 0.12 kPa after NIV (95% CI -0.04 to 0.29, limits of agreement 95% CI: -0.61 to 0.86). The linear regression analysis found a correlation R2 of 0.88 (p <0.001) at baseline and an R2 of 0.99 (p <0.001) after initiating NIV. For patients with venous blood gas analysis, the mean difference was 0.64 kPa at baseline (95% CI 0.04 to 1.24, limits of agreement 95% CI -0.72 to 2) and 0.80 kPa after NIV (95% CI 0.51 to 1.10, limits of agreement 95% CI 0.29 to 1.32), R2 0.78 (p <0.001) at baseline and R2 0.91 (p <0.001) after initiating NIV. A PaCO2/PvCO2 >8 kPa was associated with a lesser degree of agreement between the levels of PtCO2 and PaCO2/PvCO2 (p <0.001). CONCLUSION Transcutaneous PCO2 monitoring shows a good concordance with PaCO2 and is a reliable, feasible, patient-friendly and safe alternative to repeated blood gas analysis for patients with severe hypoxaemic and/or hypercapnic respiratory failure receiving emergency NIV in the emergency department. An initial blood gas analysis to evaluate the respiratory and metabolic state and to rule out a significant discrepancy compared with the transcutaneous measurement is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What is the potential role of transcutaneous carbon dioxide in guiding acute noninvasive ventilation?

BACKGROUND Transcutaneous carbon dioxide (PtcCO2 ) monitoring is rarely used in the acute hospital setting, where serial samples of arterial blood are instead taken to measure carbon dioxide tension (PaCO2 ). In this pilot observational study, we assessed the potential of PtcCO2 monitoring to calculate pH and guide management of acute noninvasive ventilation (NIV). METHODS Ten subjects with a...

متن کامل

Noninvasive Measurement of Carbon Dioxide during One-Lung Ventilation with Low Tidal Volume for Two Hours: End-Tidal versus Transcutaneous Techniques

BACKGROUND There may be significant difference between measurement of end-tidal carbon dioxide partial pressure (PetCO2) and arterial carbon dioxide partial pressure (PaCO2) during one-lung ventilation with low tidal volume for thoracic surgeries. Transcutaneous carbon dioxide partial pressure (PtcCO2) monitoring can be used continuously to evaluate PaCO2 in a noninvasive fashion. In this study...

متن کامل

Early Effectiveness of Noninvasive Positive Pressure Ventilation on Right Ventricular Function in Chronic Obstructive Pulmonary Disease Subjects with Acute Hypercapnic Respiratory Failure

Introduction: Noninvasive positive pressure ventilation (NIPPV) has become an integral tool in the management of acute hypercapnic respiratory failure (AHRF) in chronic obstructive pulmonary disease (COPD). This study was performed to evaluate the early effects of NIPPV on pulmonary artery pressure (PAP), serum N-terminal pro BNP (NT-proBNP), and ventilatory parameters in the COPD patients with...

متن کامل

Noninvasive carbon dioxide monitoring in a porcine model of acute lung injury due to smoke inhalation and burns.

In critically ill intubated patients, assessment of adequacy of ventilation relies on measuring partial pressure of arterial carbon dioxide (PaCO2), which requires invasive arterial blood gas analysis. Alternative noninvasive technologies include transcutaneous CO2 (tPCO2) and end-tidal CO2 (EtCO2) monitoring. We evaluated accuracy of tPCO2 and EtCO2 monitoring in a porcine model of acute lung ...

متن کامل

Neonatal Transcutaneous Carbon Dioxide Monitoring--Effect on Clinical Management and Outcomes.

BACKGROUND This work aimed to compare frequency of blood gas measurements per day of mechanical ventilation, occurrence of extreme blood gas CO2 values, and clinical outcomes among ventilated neonates managed with and without transcutaneous carbon dioxide (PtcCO2) monitors. This work also measures agreement between simultaneous PtcCO2 and blood gas CO2 measurements and ascertains factors that a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Swiss medical weekly

دوره 146  شماره 

صفحات  -

تاریخ انتشار 2016